2
2
2-15
2-15
Procedure of Replacement/Cleaning > Cleaning > Cleaning the Fixing Refresh Roller > Cleaning Procedure
Procedure of Replacement/Cleaning > Cleaning > Cleaning the Fixing Refresh Roller > Cleaning Procedure
4) Remove the Fixing Upper Cover [1].
• 1 Screw [2]
• 2 Hooks [3]
1x
[1]
[2]
[3]
F-2-27
CAUTION:
Be sure to check that the 2 hooks [3] are hooked when installing the Fixing Upper Cover
[1].
[3]
[3]
[3]
[3]
[1]
If the 2 hooks [3] are not hooked, the Fixing Upper Cover [1] may hit the duct [5] when
storing the Fixing Feed Unit [4].
[1]
[4]
[5]
F-2-28
F-2-29