1
1
1-43
1-43
Initial Setup > Adjustments/Settings > Display Log Menu Screen > Display of Log of ALARM-2
Initial Setup > Adjustments/Settings > Display Log Menu Screen > Display of Log of ALARM-2
■
Display of Log of ALARM-2
The log of alarm (ALARM-2) is displayed.
NOTE:
This function cannot be used in the normal setting. If it needs to be available, contact a
servicing person.
This function cannot be used in the Replacement/Cleaning mode.
1) Press [ALARM-2] on the log display menu screen.
-> The ALARM-2 screen is displayed.
F-1-83
F-1-84
2) Confirm the log of alarm (ALARM-2).
3) After confirming the log, press [OK].
●
The contents of the display
Items
Contents
No.
Sequence of alarm activation (the larger the number is, the older time alarm occurred
in) Maximum 50 cases
DATE
Date of alarm activation (2 digits both for month and date)
TIME1
Time of alarm activation (24-hr display)
TIME2
Time of alarm recovery (24-hr display)
CODE
Code of alarm activation location
DTL
Detailed alarm code
CNTR
Soft counter at the time of alarm activation
T-1-20