2. Enable the E-RDS function in the following service mode, and perform a communication test.
1. Select the following item:
• COPIER > FUNCTION > INSTALL > ERDS
2. Enter [1] from the keyboard, and press [Apply].
CAUTION:
The following settings i.e. RGW-PORT in Service mode must not be change unless there are specific instructions to do so.
Changing these values will cause error in communication with Remote Monitoring Server.
When the E-RDS function is enabled, the function to communicate with Remote Monitoring Server is enabled.
3. Select [COM-TEST] and then touch [Yes].
If the communication is successful, "OK" is displayed. If "NG" is displayed, check the network settings and Remote Monitoring
Server address (URL).
CAUTION:
The communication results with Remote Monitoring Server can be distinguished by referring to the COM-LOG. By
performing the communication test with Remote Monitoring Server, E-RDS acquires schedule information and starts
monitoring and meter reads operation.
Maintenance
■ Initializing E-RDS settings
It is possible to clear the FLASH data of E-RDS and change the E-RDS setting back to the default value.
● Initialization procedure
Follow the procedure shown below to initialize E-RDS.
1. Enter service mode as a system administrator user.
2. Select the following service mode, and press [OK] to execute.
• COPIER > Function > CLEAR > ERDS-DAT
● Setting values and data to be initialized
The following E-RDS settings, internal data, and Alarm filtering information are initialized.
• COPIER > FUNCTION > INSTALL > ERDS
• COPIER > FUNCTION > INSTALL > RGW-PORT
• COPIER > FUNCTION > INSTALL > COM-LOG
CAUTION:
If a certificate other than the CA certificate at the time of shipment has been installed, initializing the E-RDS setting will not
change the settings back to those at the time of shipment. To change the certificate back to the CA certificate at the time
of shipment, delete the certificate (install the CA certificate at the time of shipment) after initializing the E-RDS settings.
■ Report Output of Communication Error Log (COM-LOG)
A report of communication error log information on five affairs can be output.
● Report output procedure
1. Select the following service mode, and press [Yes].
• COPIER > FUNCTION > MISC-P > ERDS-LOG
3. Technical Explanation (System)
60
Summary of Contents for imageCLASS X LBP1238
Page 11: ...Safety Precautions Laser 2 Power Supply Lithium Battery 2 Toner Safety 3 Notes on works 3...
Page 15: ...Product Overview 1 Product Lineup 6 Features 8 Specifications 9 Parts Name 12...
Page 78: ...Periodical Service 4 Periodically Replaced Parts 69 Consumable Parts 70 Periodical Services 71...
Page 80: ...Consumable Parts This machine does not have any consumable parts 4 Periodical Service 70...
Page 96: ...1 2 1x 3 100 mm 5 Parts Replacement and Cleaning 86...
Page 105: ...2 3x 1x 3 3x 4 1x 2x 5 Parts Replacement and Cleaning 95...
Page 106: ...5 3x 6 7 3x 5 Parts Replacement and Cleaning 96...
Page 109: ...3 2x 4 5 2x 1x 5 Parts Replacement and Cleaning 99...
Page 110: ...6 7 8 2x 1x 2x 5 Parts Replacement and Cleaning 100...
Page 122: ...Procedure 1 1x 9x 4x 1x 5 Parts Replacement and Cleaning 112...
Page 134: ...3 4 5 2x 6 5 Parts Replacement and Cleaning 124...
Page 136: ...Adjustment 6 Actions at Parts Replacement 127...
Page 153: ...Error Jam Alarm 8 Overview 144 Error Code 148 Jam Code 154 Alarm Code 156...