![Canon imageCLASS X LBP1238 Service Manual Download Page 63](http://html1.mh-extra.com/html/canon/imageclass-x-lbp1238/imageclass-x-lbp1238_service-manual_3056623063.webp)
The following shows the procedure to turn ON replacement mode of the device to which the data is imported:
1. Set the following service mode setting value to "1":
• COPIER > OPTION > USER > RPL-IMP
NOTE:
Refer to
“List of Items Which Can Be Imported” on page 205
for the target data of replacement mode.
CAUTION:
Since replacement mode is not lifted automatically, the setting value of the foregoing service mode needs to be changed
back to "0" to return to normal mode.
Import/Export Procedure from [Settings/Registration] of Remote UI
This section describes the procedure for backing up and restoring service mode setting information by using the [Import/Export]
function in the [Settings/Registration] menu of Remote UI.
CAUTION:
• The service mode setting information can be backed up and restored only from the [Settings/Registration] menu on
Remote UI, and the operation cannot be performed from the [Settings/Registration] menu on the Control Panel.
• In the case of backing up and restoring only the setting information of the [Settings/Registration] menu or the address
book, refer to the procedure described in the e-Manual.
■ Limitations
The following limitations exist when backing up and restoring the service mode settings information from the [Settings/
Registrations] menu of remote UI.
A job must not be accepted during an import/export processing.
Except for the calibration requested by the engine, a job is not allowed to be accepted during a processing. In addition, import/
export must not be performed during execution of a job.
Firmware must not be updated during an import/export processing.
Fax cannot be received while firmware is updated during a processing. In addition, import/export must not be performed also
during firmware update.
Power must not be turned off during an import/export processing.
If power discontinuity occurs during an import processing, a rollback processing is not performed, therefore the settings
imported up to that point are reflected while the rest of the settings remain as-is.
When power discontinuity occurs during an export processing, export is not executed.
■ Procedure for Export from Remote UI ([System Management Settings] Menu)
Service mode setting information can be exported from the [System Management Settings] menu by setting the following service
mode setting value to "1".
1. Enter service mode, and set the following item to "1".
• COPIER > OPTION > USER > SMD-EXPT
NOTE:
The [SMD-EXPT] setting can be configured either from the Control Panel or from the remote UI.
2. Exit service mode, start remote UI, log in as a system administrator, and then select the following item:
• [Settings/Registration] > [Import/Export] > [Export]
3. Technical Explanation (System)
53
Summary of Contents for imageCLASS X LBP1238
Page 11: ...Safety Precautions Laser 2 Power Supply Lithium Battery 2 Toner Safety 3 Notes on works 3...
Page 15: ...Product Overview 1 Product Lineup 6 Features 8 Specifications 9 Parts Name 12...
Page 78: ...Periodical Service 4 Periodically Replaced Parts 69 Consumable Parts 70 Periodical Services 71...
Page 80: ...Consumable Parts This machine does not have any consumable parts 4 Periodical Service 70...
Page 96: ...1 2 1x 3 100 mm 5 Parts Replacement and Cleaning 86...
Page 105: ...2 3x 1x 3 3x 4 1x 2x 5 Parts Replacement and Cleaning 95...
Page 106: ...5 3x 6 7 3x 5 Parts Replacement and Cleaning 96...
Page 109: ...3 2x 4 5 2x 1x 5 Parts Replacement and Cleaning 99...
Page 110: ...6 7 8 2x 1x 2x 5 Parts Replacement and Cleaning 100...
Page 122: ...Procedure 1 1x 9x 4x 1x 5 Parts Replacement and Cleaning 112...
Page 134: ...3 4 5 2x 6 5 Parts Replacement and Cleaning 124...
Page 136: ...Adjustment 6 Actions at Parts Replacement 127...
Page 153: ...Error Jam Alarm 8 Overview 144 Error Code 148 Jam Code 154 Alarm Code 156...