![Canon imageCLASS X LBP1238 Service Manual Download Page 188](http://html1.mh-extra.com/html/canon/imageclass-x-lbp1238/imageclass-x-lbp1238_service-manual_3056623188.webp)
COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > SPLMAN
SPL84194
ON/OFF of Embedded-RDS
Detail
To set ON/OFF of Embedded-RDS function.
Use Case
When using Embedded-RDS
Adj/Set/Operate Method
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: ON, 1: OFF
Default Value
It differs according to the location.
Supplement/Memo
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
SPL32620
ON/OFF of PC-less update function
Detail
To set whether to disable the PC-less update function.
Adj/Set/Operate Method
1) Enter the setting value, and then press Apply key.
2) Turn OFF / ON the main power switch.
Caution
When LCDSFLG is 1, the setting of this item is disabled (the PC-less update function is turned
OFF).
Display/Adj/Set Range
0 to 1
0: OFF, 1: ON
Default Value
1
Related Service Mode
COPIER > OPTION > FNC-SW > LCDSFLG
Supplement/Memo
PC-less update: A function to directly download the firmware from the GDLS server and update it.
SPL37886
PC-less update: RMDS communication settings
Detail
Set whether to use HTTPS to communicate with the RMDS server.
Communication with the GDLS server is not affected.
Adj/Set/Operate Method
1) Enter the setting value, and then press Apply key.
2) Turn OFF / ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Do not use HTTPS. Use HTTP Communication.
1: Use HTTPS.
Default Value
1
SPL71700
Writing debug log to USB flash drive
Detail
To write the debug log stored in the eMMC to the USB flash drive.
Use Case
When analyzing the cause of a problem
Adj/Set/Operate Method
Select the item, and then press Yes key.
SPL01734
ON/OFF of remote UI service mode
Detail
To set whether to allow using service mode on remote UI.
Use Case
When using service mode on remote UI
Adj/Set/Operate Method
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Caution
The setting value is linked with that of RMT-SW.
Display/Adj/Set Range
0 to 1
0: OFF, 1: ON
Default Value
1
Related Service Mode
COPIER > OPTION > BODY > RMT-SW
9. Service Mode
178
Summary of Contents for imageCLASS X LBP1238
Page 11: ...Safety Precautions Laser 2 Power Supply Lithium Battery 2 Toner Safety 3 Notes on works 3...
Page 15: ...Product Overview 1 Product Lineup 6 Features 8 Specifications 9 Parts Name 12...
Page 78: ...Periodical Service 4 Periodically Replaced Parts 69 Consumable Parts 70 Periodical Services 71...
Page 80: ...Consumable Parts This machine does not have any consumable parts 4 Periodical Service 70...
Page 96: ...1 2 1x 3 100 mm 5 Parts Replacement and Cleaning 86...
Page 105: ...2 3x 1x 3 3x 4 1x 2x 5 Parts Replacement and Cleaning 95...
Page 106: ...5 3x 6 7 3x 5 Parts Replacement and Cleaning 96...
Page 109: ...3 2x 4 5 2x 1x 5 Parts Replacement and Cleaning 99...
Page 110: ...6 7 8 2x 1x 2x 5 Parts Replacement and Cleaning 100...
Page 122: ...Procedure 1 1x 9x 4x 1x 5 Parts Replacement and Cleaning 112...
Page 134: ...3 4 5 2x 6 5 Parts Replacement and Cleaning 124...
Page 136: ...Adjustment 6 Actions at Parts Replacement 127...
Page 153: ...Error Jam Alarm 8 Overview 144 Error Code 148 Jam Code 154 Alarm Code 156...