![Canon imageCLASS X LBP1238 Service Manual Download Page 179](http://html1.mh-extra.com/html/canon/imageclass-x-lbp1238/imageclass-x-lbp1238_service-manual_3056623179.webp)
COPIER (Service mode for printer) > ADJUST (Adjustment mode) > VIFADJ
FU-TMP
Adjustment of Fixing Film surface temperature setting value
Detail
To adjust the setting value of the surface temperature of the Fixing Film.
Use Case
When an image failure occurs
Adj/Set/Operate Method
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
Display/Adj/Set Range
-2 to 2
Default Value
0
CRG-HV-K
Adjustment of primary charging bias setting value (Bk)
Detail
To adjust the setting value of Bk-color primary charging bias.
Use Case
When an image failure occurs
Adj/Set/Operate Method
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
Display/Adj/Set Range
-5 to 5
Default Value
0
LS-PWR-K
Adjustment of laser light emission setting value (Bk)
Detail
To adjust the laser light emission setting value of Bk-color.
Use Case
When an image failure occurs
Adj/Set/Operate Method
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
Display/Adj/Set Range
-4 to 4
Default Value
0
TR-HV
Adjustment of transfer bias setting value
Detail
To adjust the transfer bias setting value when ATVC control is executed.
Use Case
When an image failure occurs
Adj/Set/Operate Method
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
Display/Adj/Set Range
-5 to 5
Default Value
0
FUNCTION (Operation / inspection mode)
■ INSTALL
COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > INSTALL
ERDS
ON/OFF of Embedded-RDS
Detail
To set whether to use the Embedded-RDS function.
Use Case
When using Embedded-RDS
Adj/Set/Operate Method
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
Display/Adj/Set Range
0 to 1
0: OFF
1: ON
Related Service Mode
COPIER > FUNCTION > INSTALL > RGW-PORT, COM-TEST, COM-RSLT, COM-LOG
Supplement/Memo
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
9. Service Mode
169
Summary of Contents for imageCLASS X LBP1238
Page 11: ...Safety Precautions Laser 2 Power Supply Lithium Battery 2 Toner Safety 3 Notes on works 3...
Page 15: ...Product Overview 1 Product Lineup 6 Features 8 Specifications 9 Parts Name 12...
Page 78: ...Periodical Service 4 Periodically Replaced Parts 69 Consumable Parts 70 Periodical Services 71...
Page 80: ...Consumable Parts This machine does not have any consumable parts 4 Periodical Service 70...
Page 96: ...1 2 1x 3 100 mm 5 Parts Replacement and Cleaning 86...
Page 105: ...2 3x 1x 3 3x 4 1x 2x 5 Parts Replacement and Cleaning 95...
Page 106: ...5 3x 6 7 3x 5 Parts Replacement and Cleaning 96...
Page 109: ...3 2x 4 5 2x 1x 5 Parts Replacement and Cleaning 99...
Page 110: ...6 7 8 2x 1x 2x 5 Parts Replacement and Cleaning 100...
Page 122: ...Procedure 1 1x 9x 4x 1x 5 Parts Replacement and Cleaning 112...
Page 134: ...3 4 5 2x 6 5 Parts Replacement and Cleaning 124...
Page 136: ...Adjustment 6 Actions at Parts Replacement 127...
Page 153: ...Error Jam Alarm 8 Overview 144 Error Code 148 Jam Code 154 Alarm Code 156...