Chapter 4
4-43
Memo:
For details of these adjustments, see the instructions given for basic adjustments.
If you have replaced the reader controller PCB (or initialized EEPROM), see the
descriptions given under "After Replacing the Reader Controller PCB."
4.3.2.2
After Replacing the Reader Controller PCB
0004-9327
- Before actually replacing the reader controller PCB, be sure to generate a P-PRINT
printout.
<if you are initializing the RAM of the reader controller without replacing the PCB>
- Using the SST, upload the R-CON backup data; then, download the data after initializing
the RAM so that you need not make the following adjustments.
1. Reader Unit-Related Adjustments
1) Using the SST, download the latest system software (R-CON).
2) Make the following selections in service mode:
COPIER>FUNCTION>CLEAR>R-CON; then, press the OK key to initialize the RAM.
Therefore, turn off and then on the main power.
3) Enter the following settings in service mode:
a. standard white plate white level data
COPIER>ADJUST>CCD>W-PLT-X,Y,Z
F-4-50
8 2 0 6 8 6 6 7 9 3 4 9
W- P LT- X
W- P LT- Y
W- P LT- Z
*
*
Summary of Contents for DADF-M1
Page 9: ...Chapter 1 Specifications ...
Page 17: ...Chapter 2 Functions ...
Page 66: ...Chapter 2 2 47 F 2 41 PI8 PI9 PI6 PI2 PI3 PI4 PI5 PI1 PI7 ...
Page 70: ...Chapter 3 Parts Replacement Procedure ...
Page 105: ...Chapter 4 Maintenance ...
Page 114: ...Chapter 4 4 7 F 4 4 F 4 5 23 24 25 21 26 22 29 27 28 1 31 ...
Page 156: ...Chapter 4 4 49 F 4 53 FM1 SL2 SL1 M4 M1 CL1 PCB1 M2 M3 VR1 ...
Page 158: ...Chapter 4 4 51 4 5 3 Original Placement led PCB 0003 5540 F 4 55 J201 1 3 ...
Page 159: ...Chapter 5 Error Code ...
Page 165: ...Appendix ...
Page 171: ......