Chapter 4
4-30
<If Not in Contact>
If the height adjusting rolls [1] at the left front and rear are not in contact with the reading
glass [2],turn the fixing screw [3] found at the top of the left hinge.
F-4-35
4.3.1.7
Right Angle
0003-2252
The following steps adjust the relationship between the machine's original feed direction
and the host machine's scanner system:
1) Place the Test Chart in the machine, and make a copy.
2) Check the right angle of the image in relation to the leading edge of the output (i.e., angle
A).
F-4-36
[3]
[A]
Summary of Contents for DADF-M1