Chapter 4
4-25
4.3.1.2
Angle Guide (angle of opening at 90 deg)
0003-1796
Adjust the angle of opening. If it is 90 deg, go to the next item of adjustment (i.e. tray
width).
1) Bend over the edge of the rubber cover [1], and remove the 2 mounting screws [2]; then,
detach the angle guide plate [3].
F-4-32
4.3.1.3
Sensor Output
0004-9325
Make the following adjustments if you have replaced any of the following parts:
- reader controller PCB
- post-separation sensor (PI7)
- read sensor (PI8)
- delivery reversal sensor (PI9)