66
Chapter 6
Maintenance
Adjusting the Separation Roller Gap
If documents do not feed correctly, the separation roller may not be adjusted
correctly. Adjust the separation roller gap according to the following procedure.
1
Place two sheets of paper in the document tray, and hold the Stop
button down for 10 seconds.
The shutter opens.
●
If there is no paper in the document tray, the shutter will not open.
●
The shutter will not open if the maintenance covers are open.
2
Feed one sheet of paper into the separation roller gap, then turn
the adjustment dial to move the paper smoothly into the separation
roller gap.
3
While one sheet of paper is fed into the separation roller gap,
adjust the adjustment dial so that the second sheet of paper does
not feed into the separation roller gap.
4
Remove the paper from the document tray, and close the shutter.
Do not use the adjustment dial any other time except when adjusting the
separation roller gap. Turning the adjustment dial too much may damage the
scanner.
Shutter
Separation Roller
Stop Button
Hold down for 10 seconds while a sheet of
paper is loaded, then the shutter opens.
Separation Roller Gap Adjustment
Dial
Turn the dial to the right to widen the
gap, and turn it to the left to narrow the
gap.
CAUTION
Note