Configuration
25
3.9.1
Remote Display Command Format:
The following is an example format string if using a display message on a 4", 6" and Stop/Go remote.
|<AA><CC>|<Data>!
Where:
| = Pipe character (Ox7C)
AA = Two byte address, ASCII digits (0-31)
CC = Two byte command, ASCII characters
| = Pipe character (Ox7C)
Data = Data depending on command
! = Exclamation point character (0 x21)
Commands, GT, ST, DI, DO, GR, SR, GV, DC and the feed back results are not displayed on the remote
display.
Table 3-8. Remote Display Commands
Command
Description
Examples
DM
Display message <Data> is a six charactor message.
|00DM|HELLO !
GT
Get time and date. Information gathered is sent back to the indicator so that
both the remote display and indicator match.
|00GT!
ST
Set time and date.
NOTE:
Two spaces are required between time and date entries.
Time must be entered in a 24-hour format
|00ST08:00:00 2003-01-31!
|00ST15:00:00 2003-01-31!
to obtain a P.M. time of 3:00P.M.
DI
Read digital input levels (returns “0”=LL, “1”=LH, “2”=HL, “3”=HH)
see Section 3.9.2 on page 26 for further examples
|00DI!
DO
Set digital output levels (“DO0”=LL, “DO1”=LH, “DO2”=HL, “DO3”=HH)
see Section 3.9.2 on page 26 for further examples
|00DOx!
where x references numbers 0-3
GV
Get the version number
|00GV!
DC
Dump configuration parameters (for testing purposes only)
|00DC!
Time and date are sent from the remote display in the current time format of the remote display:
Time and date are sent to the remote display in ISO format.
USA Format: HH:MM:SS AM/PM MMM/DD/YYYY
ISO Format: HH:MM:SS YYYY-MM-DD
If the real time clock is disabled in the remote display, an error message is sent back.