● Read this manual entirely before installing or operating the water heater.
● Use this appliance only for its intended purpose as described in this Use and
Care Manual.
● Be sure your appliance is properly installed in accordance with local codes and
the provided installation instructions.
● Part of your water heater unless it is specifically recommended in this manual.
● All other servicing should be referred to a qualified technician.
Installing The Water Heater
Indoor location
● Installation distances may vary by local code. It is the installer’s responsibility
to verify installation requirement.
● Make sure before installation that the gas type will use is the same type on the
data plate.
● The water heater unit should be installed by professionals. Improper installation
may cause failure or dangerous conditions such as gas leaking or explosion.
● Water heater cannot be installed in an UN-VENTED bathroom, bedroom,
basement, living room, closet, outdoor, stairway or an exit area. If installed in
an exit area, it must be at least 16.5ft or more way from the exit.
● Vent pipe should extend from the wall at least 2″. The terminal must be at least
1.64 ft away from obstruction, and must be well vented.
● Vent pipe should slope 3° downward, to avoid condensing water and protect
from rain entering.
● Vent pipe should avoid direct, strong wind because the downdraft will cause
malfunction.
● The unit should be installed far from any blockage, and with plenty of enough
space for installation and maintenance. Adequate clearances for servicing must
be provided.
● The unit should not be installed in the same room with a gas stove.
● When determining the floor clearance, a clearance of 6″ must be maintained
between the vent pipe and combustible material. A side wall clearance of 6″
and a top clearance of 12″ must be maintained.
● The vent pipe can be up 32ft in length with one elbow.
● The vent pipe should be installed with a flame retardant wall thimble. Owner
must refer to vent manufacturer’s instructions and specifications.
● The power socket connecting the water heater should be grounded properly
with a GFCI circuit protector.