year. Turn off the electrical power and gas shut off valve. Lift and release lever on
the relief valve and check the manual operation of the relief valve. You should
take precaution to avoid contact with the hot water coming out of the relief valve
and to prevent water damage.
NOTICE:
If the relief valve on the system discharges periodically, this may be due
to thermal expansion in a closed water supply system. Contact the water supplier
or local plumbing inspector on how to correct this situation. Do not plug the relief
valve.
Gas Supply
WARNING:
Do not attempt to convert this water heater for use with a different
type of gas other than the type shown on the rating plate. Such conversion could
result in hazardous operating conditions. Please have a professional connect the
gas pipe.
The manual gas appliance shut off valve must be installed at the gas connection
of the water heater at the time of installation.
The branch gas supply line to the water heater should be clean black steel pipe or
other approved gas piping material. A ground joint union or ANSI design certified
semi-rigid or flexible gas appliance connector should be installed in the gas line
close to the water heater.
The National Fuel Gas Code (NFGC) mandates a manual gas shut off valve, see
(NFGC) for complete instructions.