Inner Thimble
Section
Outer Thimble
Section
Side View
CAUTION
Follow the vent manufacturers installation instructions as design might vary from
manufacturer to manufacturer.
WARNING
Field wiring connections and electrical grounding must comply with local codes, or
in the absence of local codes with the latest edition of the National Electrical Code
ANSI/NFPA 70, or in Canada, Canadian Electrical Code, CSA C22.1 Part1.
Use UL approved Category III vent material only. No other vent material is
permitted. Owner must refer to vent manufacturer’s instructions and
specifications.
Hardwiring The Electrical Connections
●
Wiring should be carried out by a qualified electrician in accordance with local
codes.
● The water heater requires 120VAC/60Hz and should be properly grounded.
● DO NOT connect grounding wire to water pipes, gas pipes, telephone cables,
lightning conductor circuits and to grounding circuit of other equipment that
carry a ground-fault interrupter.
● An ON/OFF switch must be provided and installed for the incoming 120VAC
power.
● Wire the water heater exactly as shown below. A wiring diagram is also found
inside of the cover panel.
● A green screw is provided in the junction box for grounding connection.
● Connect the live wire to black leg wire and the neutral wire to the white neutral
wire.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify correct operation after servicing.