IMPORTANT:
Do not apply heat to the HOT or COLD water connections. Any
heat applied to the water supply fittings will permanently damage the internal
components of the water heater.
NOTICE:
If the water flow resistance of a shower head is too high, the burner in
the water heater will fail to ignite. Keep the shower head clean from debris that
could cause additional pressure drop.
NOTICE:
If using mixing valves on the outlet, choose one which prevents cold
water pressure from overcoming hot water line pressure.
DO NOT use pipes with smaller diameters than the water supply connection of
the water heater.
Be sure to connect the water inlet and the hot water outlet as shown on the water
heater. If reversed, the water heater will not function.
Installation of unions or flexible copper connections are recommended on the
HOT and COLD water lines, so that the water heater may disconnect easily for
servicing if necessary.
In regards to the hot water outlet
●
Connections between the water heater and point(s) of use should be as short
and direct as possible.
●
DO NOT use lead or non-approved plastic pipe.
●
To conserve energy and minimize heat loss, insulation of hot water piping is
recommended.
Air Relief Valve
Hot Water Tap
Drain Valve
Water Outlet