CS616 and CS625 Water Content Reflectometers
6.4.5.3 CS616 Sample Edlog Program 3
Read datalogger battery voltage and 3 CS616s hourly. CS616 enable wires are
connected to sequential datalogger control ports for automatic incrementing.
Convert CS616 period to volumetric water content. Write average of hourly
readings to final storage every 4 hours.
CS616x
CR10X
green
Single-Ended Channel x (SEx)
orange
Control Port y (Cy)
x = 1,2,3 for 3 CS616 outputs
y = 6,7,8 for 3 CS616s enables
The red leads are connected to 12Vdc and the blacks and shields are connected
to ground.
;{CR10X}
;
*Table 1 Program
01: 3600
Execution
Interval
(seconds)
1: Batt Voltage (P10)
1: 7
Loc [ batt ]
2: CS616 Water Content Reflectometer (P138)
1: 3
Reps
2: 1
SE
Channel
3: 6
C6 is first of sequential Control Ports used
4: 1
Loc
[
period_1
]
5: 1.0
Mult
6: 0.0
Offset
3: Polynomial (P55)
1: 3
Reps
2: 1
X Loc [ period_1 ]
3: 4
F(X) Loc [ vwc_1 ]
4: -0.0663 C0
5: -0.0063 C1
6: 0.0007 C2
7: 0.0
C3
8: 0.0
C4
9: 0.0
C5
;
4: If time is (P92)
1: 0000
Minutes (Seconds --) into a
2: 240
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
20