CS616 and CS625 Water Content Reflectometers
5: Average (P71)
1: 4
Reps
2: 4
Loc [ vwc_1 ]
*Table 2 Program
02: 0.0000 Execution
Interval
(seconds)
*Table 3 Subroutines
End Program
-Input Locations-
1 period_1 5 1 1
2 period_2 9 1 1
3 period_3 17 1 1
4 vwc_1 5 1 1
5 vwc_2 9 1 1
6 vwc_3 17 1 1
7 batt 1 0 1
6.4.5.4 CS616 Sample Edlog Program 4
Measure soil temperature with 107 probe and CS616 output period every four
hours. Correct CS616 output period for temperature and write result to
datalogger final storage.
Sensor lead
CR10X
CS616 green
Single-Ended Channel 2 (SE2)
CS616 orange
Control Port 4 (C4)
107 red
Single-Ended Channel 1 (SE1)
107 black
Excitation 1 (E1)
107 purple
Analog Ground (AG)
107 clear
Ground (G)
The CS616 red leads are connected to 12 Vdc and the blacks and shields are
connected to ground.
;{CR10X}
;
*Table 1 Program
01: 60
Execution
Interval
(seconds)
;set reference temperature for temperature correction
1: Z=F x 10^n (P30)
1: 20
F
2: 0
n,
Exponent
of
10
3: 2
Z Loc [ Tref ]