User Guide
23
Baud
= 6, 19200 baud.
Baud
= 7, 38400 baud.
Baud
= 8, 57600 baud.
Baud
= 9, 76800 baud.
Baud
= 10, 115200 baud (default).
Bits_Parity
= 0, 8 bits, no parity, 1 stop bit (default).
Bits_Parity
= 1, 7 bits, even parity, 1 stop bit.
Bits_Parity
= 2, 7 bits, odd parity, 1 stop bit.
Delay
is the delay time in mS to TX (RS485 half-duplex mode only).
Range 0-1000mS, default 100mS.
STATUS
No parameters
Outputs CS135, serial number, DSP OS version, TOP OS version, PSU
OS version, time & date, blower heater mode, internal heater mode,
serial parameters, message parameters, tilt angle, units,
temperature/humidity, hood temperature, height offset, alarms,
warnings, PSU voltage and backup battery voltage.
Note: Refer to Section 5.1.5 for more information on this command.
TERMINAL
Terminal
Timeout
Sets CRC16-CCITT checking and the user terminal time out.
Terminal
= 0, CRC16-CCITT off (default).
Terminal
= 1, CRC16-CCITT on (reserved for future OS).
Timeout
is the delay in minutes from 1 to 15 where the terminal will
automatically close if no characters are sent to the CS135. The default
is 10 minutes.
TIME
Date_Time
Date is format yyyy/mm/dd
Time is format hh:mm:ss
yyyy=year, mm=month, dd=day
hh=hours, mm=minutes, ss=seconds
(i.e. time 2000/01/01 10:00:00, would set the time to January 1
st
2000 at
10:00:00)
Note: The set time could drift by up to ±14 seconds a day.
UNITS
Units
Sets measurement units and tilt correction for cloud height and vertical
visibility.
Units
= 0, metres corrected by tilt.
Units
= 1, metres not corrected by tilt.
Units
= 2, feet corrected by tilt (default).
Units
= 3, feet not corrected by tilt.
5.1.4 MCFG command message types
The MCFG commands “Message_ID_x” parameter defines the following output
types. Refer to Section 6 for further information on message output types.
Message_ID_x type
Description
000 No
message
001 (default)
Campbell Scientific Message 1, no sky condition, no profile data
002
Campbell Scientific Message 2, no sky condition, profile data, 2048 range bins, 5m resolution
003*
Campbell Scientific Message 3, sky condition, no profile data
004*
Campbell Scientific Message 4, sky condition and profile data, 2048 range bins, 5m resolution
101
CL31 Message 1, 770 range bins, 10m resolution
102
CL31 Message 1, 385 range bins, 20m resolution
103
CL31 Message 1, 1500 range bins, 5m resolution
104
CL31 Message 1, 770 range bins, 5m resolution
105
CL31 Message 1, No profile data
106
CL31 Message 1, Full CS135 output, 2048 range bins, 5m resolution
107*
CL31 Message 2, 770 range bins, 10m resolution
108*
CL31 Message 2, 385 range bins, 20m resolution
Summary of Contents for CS135
Page 1: ...CS135 Ceilometer User Guide Issued 18 3 13 Copyright 2012 2013 Campbell Scientific Ltd CSL 950...
Page 2: ......
Page 4: ......
Page 6: ......
Page 19: ...User Guide 11 Fig 4 2 Setting the Tilt Angle...
Page 62: ...CS135 Ceilometer 54 LINE 3 ETX CR LF ETX End of Text Character CR LF Carriage Return Line Feed...