Installation (continued)

 

 
 
 

 

Improper  

 use of 

grounding plug can result in 
a possible risk of electrical 
shock!
 

Do not use a  

 grounding adapter 

with this product!

2.  If repair or replacement of cord or 

plug is necessary, do not connect 
grounding wire to either flat blade 
terminal. The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire.

 

Never connect  

 green (or green 

and yellow) wire to a live terminal.

3.  Check with a qualified electrician 

or serviceman if grounding 
instructions are not completely 
understood, or if in doubt as 
to whether product is properly 
grounded. Do not modify plug 
provided; if it will not fit outlet, 
have proper outlet installed by a 
qualified electrician.

 

Overheating, short  

 circuiting and fire 

damage will result from inadequate 
wiring.

LUbrIcatIOn

This is an oilless product and 

DOeS 

nOt

 require lubrication to operate.

Pre-Operation

beFOre FIrSt Start-UP
break-In PrOceDUre

(Complete this procedure before 
using compressor for the first time. 
Once completed, it is not necessary to 
repeat.)
1.  Turn regulator knob fully clockwise 

(to the right) to open air flow.

2. 

Do not

 attach a hose or any other 

fitting to the compressor.

3.  Turn 

On / OFF

 switch to 

OFF

 

position.

4.  Plug in power cord.
5.  Turn 

On / OFF

 switch to 

On

 

position and run compressor for 30 
minutes.

6.  Turn 

On / OFF

 switch to 

OFF

 

position.

7.  Unplug power cord.

The compressor is now ready for use.

beFOre each Start-UP
OPeratInG PrOceDUre

1.  Turn regulator knob fully 

counterclockwise (to the left) to 
close air flow. 

2.  Connect air hose to outlet of 

regulator.

3.  Turn 

On / OFF

 switch to 

OFF

 

position.

4.  Plug in power cord.
5.  Turn 

On / OFF

 switch to 

On

 

position and let compressor run 
until it reaches automatic shutoff 
pressure.

6.  Attach tire chuck or tool to end of 

hose.

7.  Turn regulator knob clockwise (to 

the right) to desired pressure of 
tool being used.

Operation

Start-UP

 

Do not attach air  

 tools to open end 

of the hose until start-up is completed 
and the unit checks OK.

On / OFF cycLInG OF cOMPreSSOr

In the 

On / aUtO

 position, the 

compressor pumps air into the tank. 
When a shut-off (preset “cut-out”) 
pressure is reached, the compressor 
automatically shuts off.

If the compressor is left in the  

On / aUtO

 position and air is depleted 

from the tank by use of a tire chuck, 
tool, etc., the compressor will restart 
automatically at its preset “cut-in” 
pressure. When a tool is being used 
continuously, the compressor will cycle 
on and off automatically. 

In the 

OFF

 position, the pressure 

switch cannot function and the 
compressor will not operate. Make 
sure switch is in 

OFF

 position when 

connecting or disconnecting power 
cord from electrical outlet.

PreSSUre GaUGeS

Gauge attached to regulator indicates 
air pressure going to hose (and any 
tool attached to end of hose).

Gauge attached to pressure switch 
indicates air pressure in tank.

MOIStUre In cOMPreSSeD aIr

Moisture in compressed air will 
form into droplets as it comes 
from an air compressor pump. 
When humidity is high or when 
a compressor is in continuous use 
for an extended period of time, 
this moisture will collect in the 
tank. When using a paint spray or 
sandblast gun, this water will be 
carried from the tank through the 
hose, and out of the gun as droplets 
mixed with the spray material.

IMPOrtant:

 This condensation 

will cause water spots in a paint 
job, especially when spraying 
other than water based paints. If 
sandblasting, it will cause the sand 
to cake and clog the gun, rendering 
it ineffective.
A filter in the air line, located as 
near to the gun as possible, will 
help eliminate this moisture.

TEST

RESET

Figure 3 - Grounding Method

Grounded 

Outlet

Grounding 

Pin

Summary of Contents for IN614207AV

Page 1: ...t information that if not followed may cause damage to equipment NOTE Information that requires special attention Safety Guidelines This manual contains information that is very important to know and...

Page 2: ...immediately for the cause Vibration is generally a warning of trouble 11 To reduce fire hazard keep engine motor exterior free of oil solvent or excessive grease An ASME code safety relief valve with...

Page 3: ...ot locate the compressor air inlet near steam paint spray sandblast areas or any other source of contamination This debris will damage the motor Grounding instructions 1 This product is for use on a n...

Page 4: ...d let compressor run until it reaches automatic shutoff pressure 6 Attach tire chuck or tool to end of hose 7 Turn regulator knob clockwise to the right to desired pressure of tool being used Operatio...

Page 5: ...ased when you pull on the ring or if it does not close automatically it MUST be replaced Drain Tank With compressor shut off and pressure released drain moisture from tank by opening drain valve under...

Page 6: ...e drain valve 1 Tighten 2 Check valve leaking 2 Remove check valve Clean or replace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detecte...

Page 7: ...Check valve includes part 29 30 FP209532AV 1 11 M4 x 0 7 x 6 screw 1 12 M6 x 1 0 x 10 screw l 4 13 Drain valve D 1403 1 14 Rubber foot tank u 3 15 Wire pressure switch to power switch FP209523AV 1 16...

Page 8: ...lubricants and adjustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any componen...

Page 9: ...CONSERVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher le...

Page 10: ...est g n ralement une indication d un probl me 11 Pour r duire le risque d incendie garder l ext rieur du moteur libre d huile de solvants et de graisse excessive Une soupape de s ret ASME avec une cl...

Page 11: ...ctrique en fournissant un fil d chappement pour le courant lectrique Ce produit est quip avec un cordon qui a un fil de terre avec une fiiche de terre La fiche doit tre branch e dans une prise de cour...

Page 12: ...le cordon d alimentation 5 Mettre l interrupteur marche arr t la position ON marche et faire fonctionner le compresseur jusqu ce qu il atteigne la pression d arr t automatique 6 Fixer le mandrin de p...

Page 13: ...ir en tirant sur l anneau ou si elle ne se ferme pas automatiquement il FAUT la remplacer Purger le r servoir Avec le compresseur hors circuit et la pression dissip e purger l humidit du r servoir en...

Page 14: ...remplacer 3 Connexions desserr es aux raccords tubes etc 3 V rifier toutes les connexions avec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du rub...

Page 15: ...29 et 30 FP209532AV 1 11 Vis M4 x 0 7 x 6 1 12 Vis M6 x 1 0 x 10 l 4 13 Robinet de purge D 1403 1 14 Pied en caoutchouc R servoir u 3 15 Fil pressostat avec interrupteur FP209523AV 1 16 Cordon d alim...

Page 16: ...ifiants filtres et joints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos...

Page 18: ...Mantenga los dedos alejados del compresor cuando est funcionando las piezas en movimiento o calientes le ocasionar an heridas y o quemaduras 10 Si el equipo comienza a vibrar excesivamente APAGUE la...

Page 19: ...e Instalaci n Colocaci n Es extremadamente importante instalar el compresor en un rea limpia seca y bien ventilada El compresor debe estar ubicado sobre una superficie firme y nivelada donde la temper...

Page 20: ...FF apagado 4 Enchufe el cable de corriente 5 Coloque el interruptor de encendido apagado en la posici n ON encendido Deje que el compresor funcione durante 30 minutos 6 Coloque el interruptor de encen...

Page 21: ...eas de aire IMPORTANTE El compresor debe colocarse lo m s lejos posible del rea de pulverizaci n seg n lo permita la Humedad en el aire comprimido La humedad que se acumula en el aire comprimido se co...

Page 22: ...naje floja 1 Ajuste 2 Fugas en la v lvula de retenci n 2 Retire la v lvula de retenci n Limpie o reemplace 3 Conexiones flojas en los accesorios tuber a etc 3 Revise todas las conexiones con una soluc...

Page 23: ...uye piezas No 29 y 30 FP209532AV 1 11 Tornillo M4x0 7x6 1 12 Tornillo M6x1 0x10 l 4 13 V lvula de drenaje D 1403 1 14 Pata de caucho Tanque u 3 15 Cable interruptor de presi n a interruptor de corrien...

Page 24: ...s etc F Art culos adicionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contra...

Reviews: