PORTABLE COMPRESSOR

USER GUIDE

AFTER SALES SUPPORT

www.einhell.co.uk

0151 649 1500

WZK 182

05/2013

1890 946 244

Now you have purchased a Workzone® product you
can rest assured in the knowledge that as well as your
3 year parts and labour warranty you have the added
peace of mind of dedicated helplines and web support.

WZK_182_UK_SPK7.indb   1

22.11.12   14:00

Содержание WZK 182

Страница 1: ... 1500 WZK 182 05 2013 D 1890 946 244 Now you have purchased a Workzone product you can rest assured in the knowledge that as well as your 3 year parts and labour warranty you have the added peace of mind of dedicated helplines and web support WZK_182_UK_SPK7 indb 1 22 11 12 14 00 ...

Страница 2: ... manufacturer s 3 year warranty and an outstanding after sales service through our dedicated Helpline We hope you will enjoy using your purchase for many years to come If you require technical support or in the unlikely event that your purchase is faulty please telephone our Helpline for immediate assistance Faulty product claims made within the 3 year warranty period will be repaired or replaced ...

Страница 3: ... www einhell co uk D 1890 946 244 WZK 182 05 2013 Tableof contents 04 Safety information 09 Items supplied 10 Layout 11 Use 12 Before starting the equipment 13 Operation 17 Data 21 Warranty Certificate WZK_182_UK_SPK7 indb 3 22 11 12 14 00 ...

Страница 4: ...ere to the safety information and instructions set out below may result in electric shock fire and or serious injury Keep all the safety information and instructions in a safe place for future use m Caution The following basic safety actions must be taken when using this compressor in order to protect the user from electric shocks and the risk of injury and fire Read and follow these instructions ...

Страница 5: ...city range 7 Wear suitable work clothes Never wear loose fittings clothes or jewelry They may get caught in moving parts Rubber gloves and non slip shoes are recommended when working outdoors Wear a hair net if you have long hair 8 Do not use the cable for purposes other than that for which it is designed Do not carry the compressor by its cable and do not use the cable to pull the plug out of the...

Страница 6: ...e operating instructions damaged guards and parts have to be repaired or replaced by a customer service workshop Damaged switches have to be replaced by a customer service workshop Never use an electric power tool with a switch that cannot be turned on and off 15 Important For your own safety you must only use the accessories and additional units listed in the operating instructions or recommended...

Страница 7: ...e compressor must be kept free of impurities that could cause fires or explosions in the compressor When releasing the hose coupling be sure to hold the hose coupling piece with your hand to protect yourself against injury from the rebounding hose Wear safety goggles when working with the blow out pistol Foreign bodies or blown off parts can easily cause injuries Do not blow at people with the blo...

Страница 8: ...SALES SUPPORT t 0151 649 1500 www einhell co uk D 1890 946 244 WZK 182 05 2013 Note the instructions for use Wear ear muffs Beware of electrical voltage Beware of hot parts WZK_182_UK_SPK7 indb 8 22 11 12 14 00 ...

Страница 9: ...to see if all the items are supplied Inspect the equipment and accessories for transport damage If possible keep the packaging until the end of the warranty period IMPORTANT The equipment and packaging material are not toys Do not let children play with plastic bags plastic sheets and small parts There is a risk of choking and suffocating Portable Compressor Tyre pressure gauge Blow out adapter 8 ...

Страница 10: ... co uk D 1890 946 244 WZK 182 05 2013 3 Layout 1 Housing 2 Pressure gauge 3 Compressed air hose with quick lock coupling 4 On Off switch 5 Transport handle 6 Tyre pressure gauge 7 Blow out adapter 5 1 4 6 3 d 1 2 WZK_182_UK_SPK7 indb 10 22 11 12 14 00 ...

Страница 11: ...t is designed to handle Any other use is deemed to be a case of misuse The user operator and not the manufacturer will be liable for any damage or injuries of any kind resulting from such misuse Please note that our equipment has not been designed for use in commercial trade or industrial applications Our warranty will be voided if the equipment is used in commercial trade or industrial businesses...

Страница 12: ...ompressor may only be used in suitable rooms with good ventilation and an ambient temperature from 5 C to 40 C There must be no dust acids vapors explosive gases or inflammable gases in the room The compressor is designed to be used in dry rooms It is prohibited to use it in damp conditions During operation place the compressor on the rubber feet on the compressor rear wall Mains connection Before...

Страница 13: ...g Insert the nipple of the air tool into the quick lock coupling the sleeve will spring forward automatically Disconnecting Pull back the sleeve and remove the tool Important When releasing the quick lock coupling be sure to hold the coupling piece to protect yourself against injury from the rebounding hose Tyre pressure gauge with adapters Fig 2 Item 6 Working pressure in bar 0 8 Range of applica...

Страница 14: ... blowing out hollow spaces or hard to reach areas as well as for cleaning soiled equipment The infinitely variable trigger lever allows an exact dosing of compressed air 6 8 2 6 7 3 Instructions for the adapter set For information on the correct use of the adapters for the various valves please refer to the following overview Ball needle Figure 4 Range of applications For inflating balls The ball ...

Страница 15: ...nge of applications For all valves with an internal diameter of 8 mm or more You can use this adapter to inflate airbeds pools or boats TIP Insert the adapter 3 into the valve as shown in Figure 6 drawing d Important The valve cap must be opened a little by being pressed together slightly Adapter 4 Figure 7 Range of applications For screw valves This adapter can be used for all conventional boats ...

Страница 16: ...ange of applications For deflation valves You can find a deflation valve combined with other valves standard valve screw valve etc on many large articles such as an inflatable mattress Conical universal adapter Figure 9 10 Range of applications For inflating airbeds and similar 8 9 10 WZK_182_UK_SPK7 indb 16 22 11 12 14 00 ...

Страница 17: ...an cloth or blow it down with compressed air at low pressure We recommend that you clean the equipment immediately after you use it Clean the equipment regularly with a damp cloth and some soft soap Do not use cleaning agents or solvents these may be aggressive to the plastic parts in the equipment Ensure that no water can get into the interior of the equipment You must disconnect spraying tools f...

Страница 18: ...eused or recycled The equipment and its accessories are made of various types of material such as metal and plastic Defective components must be disposed of as special waste Ask your dealer or your local council Technical data Mains connection 220 240 V 50 Hz Motor rating kW 1 1 Operating mode S3 15 10 min Compressor speed min 1 3550 Operating pressure bar max 8 Theoretical suction rate l min 180 ...

Страница 19: ... down If necessary remedy the cause of the overheating The compressor starts but there is no pressure 1 The non return valve has a leak 2 The seals are damaged 1 Replace the non return valve 2 Check the seals and have any damaged seals replaced by a service center The compressor starts but the tools do not 1 Loose hose connections 2 Leak in a quick lock coupling 1 Check the compressed air hose and...

Страница 20: ...eturning the equipment to the manufacturer the owner of the electrical equipment is obliged to ensure that the equipment is properly disposed of if relinquishing ownership The old equipment can be returned to a suitable collection point that will dispose of the equipment in accordance with the national recycling and waste disposal regulations This does not apply to any accessories or aids without ...

Страница 21: ...he end of the warranty period This also applies if an on site service is used The warranty is valid for a period of three years starting from the purchase date Keep your sales receipt in a safe place as it is your proof of purchase Your statutory rights are not affected by this warranty During the warranty period you can report defective equipment by phone or by writing to the service address belo...

Страница 22: ...Twelve Quays Birkenhead Wirral CH 41 1LF sales einhell co uk technical einhell co uk AFTER SALES SUPPORT www einhell co uk t 0151 649 1500 WZK 182 05 2013 D 1890 946 244 YEAR WARRANTY IMPORTANT KEEP THIS FORM SAFE Only complete and return this form to the address below in the unlikely event of a warranty claim if you are requested by the manufacturer to return the item for replacement Then please ...

Страница 23: ...23 AFTER SALES SUPPORT t 0151 649 1500 www einhell co uk D 1890 946 244 WZK 182 05 2013 WZK_182_UK_SPK7 indb 23 22 11 12 14 00 ...

Страница 24: ...EH 11 2012 01 WZK_182_UK_SPK7 indb 24 22 11 12 14 00 ...