EMC_SPEC018_C2.doc
Rev. D
–
2020 05 19
14/44
Install & Operating Manual
CamSafe
General Assembly of Housings / Collectors (continued)
Repeat for each housing.
In between housings, flange access is easier from the back side,
using a ratchet. Do not block bolts yet at this point.
Place gasket(s) on the next flange
level.
Assembly ready for the next level
(housings or collector).
Manipulate the upper collector
using the lifting rings.
Check for proper alignment.
Take off the housing doors …
… to
access flange bolts positions
close to the collar.
Tighten to
35 Nm
torque.
13
M8
13
M8
35
Nm