Page
15
- Manual
FA01798-EN
- 01/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
4
Fasten the support to the rack using the grub screws supplied.
5
The limit-switch tab magnet must be perpendicular to the magnetic sensor.
6
Fasten the limit-switch tab using the screw (supplied).
1
Close the gate.
2
Insert the magnetic closing limit-switch tab on the rack.
3
The tab magnet must be between 10 and 30 mm from the magnetic sensor.
~ 20
10 < 30
4
Fasten the support to the rack using the grub screws supplied.
5
The limit-switch tab magnet must be perpendicular to the magnetic sensor.
6
Fasten the limit-switch tab using the screw (supplied).