Impact test
Activate/deactivate test mode for impact tests. With the function on, the operator does not signal errors connected to obstacle detection after more than one consecutive
impact.
Pre-set the travel parameters, according to the gate weight, to use for impact tests.
Test mode is deactivated automatically after 1 hour.
With the function on, the display shows the
icon.
Configuration >
Gate travel settings
Impact test
Activate test mode
Deactivate test mode
Leaf weight
Select the gate weight value closest to the real weight:
400 (Default)/600/800 kg for BKX08
800 (Default)/1000/1200 kg for BKX12
Apply pre-set value
Configure the travel parameters according to the set leaf weight.
The parameter is only displayed after travel has been calibrated. See the [Travel
calibration] function.
Total stop
Activate or deactivate input 2-1. If it is activated, the input is used as a normally closed contact.
With the input open, this function excludes all commands, including any automatic closing.
Configuration >
Wired safety devices
Total stop
Deactivated (Default)
On
CX input, CY input, CZ input, CK input
Associate a function with the input CX CY CZ CK
Configuration >
Wired safety devices
CX input
CY input
CZ input
CK input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate closure once the obstruction has been
removed, even if the gate is not in motion
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
r8 = Reclose while opening (sensitive edges with 8K2 resistor)
r7 (two sensitive edges) = Reopen while closing (pair of sensitive edges with 8K2 resistor)
r8 (two sensitive edges) = Reclose while opening (pair of sensitive edges with 8K2 resistor)