Safety devices test
Check that the photocells connected to the selected inputs are operating correctly, after each opening and closing command.
Run the test by connecting the photocells to the TS terminal [see paragraph on Safety devices].
Configuration >
Wired safety devices
Safety devices test
Deactivated (Default)
CX _ _ _
_ CY _ _
CX CY _ _
_ _ CZ _
CX _ CZ _
_ CY CZ _
CX CY CZ _
_ _ _ CK
CX _ _ CK
_ CY _ CK
CX CY _ CK
_ _ CZ CK
CX _ CZ CK
_ CY CZ CK
CX CY CZ CK
RIO ED T1 and RIO ED T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
Configuration >
RIO safety devices
RIO ED T1
RIO ED T2
Deactivated (Default)
P0 = It stops the gate and excludes automatic closing. Use a control device to resume
movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
RIO PH T1 and RIO PH T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
Configuration >
RIO safety devices
RIO PH T1
RIO PH T2
Deactivated (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop. Only with [Automatic close] activated.
P4 = Obstacle standby.
P13 = Reopening during closure with immediate stop once the obstacle has been removed,
even with the gate not in motion.
BUS photocell
Associate a function with the input for the BUS photocells.
<n> is between 1 and 8 and corresponds to the address set on the photocell dip-switch
The function only appears if there is a BUS photocell connected.
Configuration>
BUS Devices
BUS Photocell 1
Photocell BUS 2
Photocell BUS 3
Photocell BUS 4
Photocell BUS 5
Photocell BUS 6
Photocell BUS 7
Photocell BUS 8
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C13 = Reopen while closing, with immediate closure once the obstruction has been
removed, even if the gate is not in motion
Open