Page
8
- Manual
FA01798-EN
- 01/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Size
340
195
226
182
145
350
272
385
63
63
64
190
101
Usage limitations
MODELS
BKX12AGF
BKX12RGF
Pinion module
4
4
Maximum gate-leaf length (m)
20
20
Maximum gate-leaf weight (kg)
1200
1200
Fuse table
MODELS
BKX12AGF
BKX12RGF
Line fuse
3.15A-F
6.3A-F
Control-board fuse
1.6A-T
1.6A-T
Accessory fuse
1.6A-F
1.6A-F
Motor fuse
15A-T
15A-T
Technical data
MODELS
BKX12AGF
BKX12RGF
Power supply (V - 50/60 Hz)
230 AC
120 AC
Motor power supply (V)
24 DC
Board power supply (V)
20 AC
Standby consumption (W)
5
Power (W)
270
Colour
7024
Operating temperature (°C)
-20 ÷ +55
Storage temperature (°C)*
-20 ÷ +70
Thrust (N)
800
Maximum operating speed (m/min)
20
Sound pressure level (dB A)
≤70
Protection rating (IP)
54
Insulation class
I
Reduction ratio (i)
1:32
Weight (kg)
17
Average life (cycles)**
250000
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life specified should be understood purely as an indicative estimate. It applies to normal usage conditions and where the product has been
installed and maintained in compliance with the instructions provided in the CAME technical manual. The average product life is also affected, including significantly,
by other variables such as, but not limited to, climatic and environmental conditions. The average product life should not be confused with the product warranty.