Safety devices
Photocells
Configure contact CX or CY (NC), input for safety devices such as photocells, which comply with EN 12978 regulations.
See
[CX input]
or
[CY input]
in:
- C1 reopening during closing. when the gate is closing, opening the contact causes the inversion of movement until opening is complete;
- C2 close back up during opening. When the gate is opening, opening the contact triggers the inversion of movement until the gate is completely
closed.
- C3 partial stop. Gate stop, if moving, with resulting automatic closing (if the automatic closing function is activated);
- C4 obstruction wait. Gate stops, if it is moving, and once the obstruction is removed, it resumes its movement.
If unused, contacts CX and CY should be deactivated during programming.
Signaling devices
Connection output for a flashing light (contact rated for: 230 V AC - 25 W
max) or paired with a cycle lamp (Contact rated for: 230 V - 60 W max).
See the
[Lamp Output]
in the
[FUNCTIONS]
menu.
Gate open warning output (contact rated for: 24 V AC
- 3 W max).