Page 1: ...Instruction Manual for the Manufactured by E SL 1800 Series...

Page 2: ...allation must conform to Standards EN 12453 and EN 12445 The safety level of the automated system must be C D 10 Before attempting any job on the system cut out electrical power and disconnect the bat...

Page 3: ...ormer coupled with control board that switches the voltage to DC to power the motor The MASTER card can be programmed and is used to set the follow ing function logics work times by self learning and...

Page 4: ...2 1 Tools Needed for Installation 3 1 Manual Operation 4 1 Installation of Base Operator and Limits 5 1 5 Temporary Safety Jumpers Power 6 1 6 3 Programming 7 1 7 3 Control Board Overview 8 1 8 3 Conn...

Page 5: ...d 500 mA Torque Nm 13 5 Gate speed 3 4 per second Operating ambient temperature 4 to 131 Deg F Operator weight lbs 19 Protection class IP 44 Gate leaf max length ft Up to 25 Gate leaf max weight lbs U...

Page 6: ...weight of the gate to be automated Dimensions and weight must match those indicated in the technical specifications Make sure the leaves move smoothly without any irregular friction during entire tra...

Page 7: ...ower to your operator From 0 300 16 gauge 2 conductor stranded direct burial wire will be needed From 301 600 14 gauge 2 conductor stranded direct burial wire will be needed If the gate is more than 6...

Page 8: ...4 1 Manual Operation 1 Open the protective key cover by turning the counter clock wise 2 Turn the provided key in the lock 3 Rotate the dial clockwise...

Page 9: ...late 1 Find the distance the foundation plate must be from your gate The foundation plate must be located as shown in example A right closing or example B left closing to ensure the rack and pinion me...

Page 10: ...the bottom of the foundation plate Important check levelness of plate and measurements from gate right away before the concrete sets and the foundation plate is fixed to the pad Concrete Slab Tips Cr...

Page 11: ...n to the right 2 Feed any wires up through the opener while installing the opener to the base 1 Manually take the leaf to its close position 2 Lay the first piece of rack at the appropriate level and...

Page 12: ...installation Make sure that during the gate travel all the rack elements mesh correctly with the pinion Do not on any account weld the rack elements either to the spacers or to each other When you ha...

Page 13: ...the magnets as seen in the picture so it is triggering the limit 3 Repeat for open position The correct positioning of the closed plate can be checked later after powering up the unit The FCC limit li...

Page 14: ...terminal strips on the control board are easily removed for wiring Simply pull straight out on the terminal strip to remove it from the board It will slide right off Slide it back on when you are fin...

Page 15: ......

Page 16: ...s are only warranted if the internal fuse is not blown If the fuse is blown an outside factor shorting surge water etc has caused the transformer not to function 3 Plug the transformer into a 110 V AC...

Page 17: ...vided in the control box hardware bag for jumping these terminals to common COM during the set up process It is recommended not to use any accessories until setup and programming are complete NOTE If...

Page 18: ...e the appropriate lights are lit 2 The display should show 3 Press and hold down P2 until the display shows parameter A with the corresponding number that is currently default or previously pro gramme...

Page 19: ...put H1 H2 H3 H4 1 10 2 20 3 30 4 40 Percentage of run time in slow down I0 I1 0 Slow down speed quarter speed 1 slow down speed half speed L0 L1 0 encoder only 1 limits and encoder Encoder is a device...

Page 20: ...and COM with a wire This will begin your gate in the CLOSING DIRECTION and the LED display will read Pr 5 When the closing limit switch is reached the motor pauses for approximately 2 seconds and the...

Page 21: ...tripped STOP Stop command not activated Stop command activated FSW CL Closing safety device not tripped Closing safety device tripped FSW OP Opening safety device not tripped Opening safety device tr...

Page 22: ...W CL FSW OP terminals These normally closed terminals are for safety devices during the closing CL and opening OP cycles of the gate If a safety device is not being used in this termi nal the operator...

Page 23: ...nd corner of board used for power and back up power VAC terminals The input terminals for the supplied 24V transformer Polarity is not an issue for this terminal BAT BAT terminals Input terminals for...

Page 24: ...e opener to be active this cir cuit must be closed When a device opens this circuit it stops the motion of the gate operator This circuit is the main circuit for safety devices i e photo eyes safety l...

Page 25: ...al photos to the technician This is done in your best interest to save unnecessary shipping expenses and time lost Many times we can come up with solutions to issues by seeing pictures that relay info...