8.2
Control Board Overview
Caution!
Do not run 110V AC power direct to the board. This will cause permanent damage to both
boards and void your warrantee.
Caution!
M1 -
Located on the bottom left of the board, these terminals are for accessories and safety de-
vices.
•
OPEN A - terminal.
This is the most common terminal for accessories. Accessories utilizing a nor-
mally open contact to set the gate in motion will be attached to this terminal and the COM terminal
(common or also know as ground).
•
OPEN B - terminal.
This terminal is for opening the first leaf only in dual gate operations. It is a
normally open contact that must be used in conjunction with the COM terminal.
•
STOP - terminal.
This is a normally closed terminal that is used for gate motion stopping emergency
commands.
If a safety device is not being used in this terminal the operator must have a jumper
ran from this terminal to the COM terminal in order to operate.
•
FSW CL, FSW OP - terminals.
These normally closed terminals are for safety devices during the
closing (CL) and opening (OP) cycles of the gate.
If a safety device is not being used in this termi-
nal the operator must have a jumper ran from this terminal to the COM terminal in order to
operate.
•
COM2 - terminal.
This is a common, or sometimes referred to as ground, terminal. It is used in con-
junction will
ALL
accessories and safety devices.
M2-
Located on the left center bottom of the board, these terminals are for limit switches.
•
SIG., ENC1, ENC2 - terminals. Already connected, do not disconnect.
•
COMF -
Common terminal to make the needed normally closed connections for the limit switches.
•
FCC -
Normally closed contact. This terminal is connected with the COMF through the limit
switch. When tripped (connection opened) it stops the motion of the first operator. (
If not being
used, this terminal must be jumped with COMF)
•
FCA -
Normally closed contact. This terminal is connected with the COMF through the limit
switch. When tripped (connection opened) it stops the motion of the first operator. (
If not being
used, this terminal must be jumped with COMF)