background image

recommended is 10Nm (for 4” motors).
Attach the cable to the pump with the cable guard
and place the filter on the suction lantern. 
Follow separate operating instructions (if available)
of the motor.

4. Electrical connection

Electrical connection must be carried
out only by a qualified electrician in
accordance with local regulations.

Follow safety standards.

The unit must be pro-
perly earthed (groun-
ded), also with a non-
metallic delivery pipe.

Make sure the frequency
and mains voltage cor-
respond with the name
plate data.

The 

control panel

must

contain:

a device for disconnection
from the mains (switch)
with a contact separation
of at least 3 mm in all
poles;

an adequate motor pro-
tector for the current
indicated on the name-
plate;

a capacitor for the

SDM

single-phase pumps, in
accordance

with

the

data indicated on the
motors themselves.

For pumps with power rating above 11 kW, it is
advisable to provide the control panel with Y/ Δ
or impedance starting.
Install electrodes to protect the pump against dry
running.

4.1. Connection of cables

Feed cables have to be chosen on the basis of
power, distance, voltage drop and temperature.
For connection of cables in the well, use thermo-
shrinking insulation sheathes or other systems
used for submerged cables.
Before lowering the motor into the well, use appro-
priate instruments to measure continuity between
phases and perform an isolation test between each
single phase and the earth conductor.

4.2. Operation with frequency converter

Adjust the frequency converter so that the limiting
values of min. 30 Hz and max. 60 Hz will not be
exceeded.
The maximum running up time from 0 to 30 Hz
and running down time from 30 to 0 Hz for fre-
quency-converter operation is 1 second.

5. Starting

ATTENTION: never run the pump dry,
not even for a short trial run. 

Start the pump with the gate valve regula-
ted to minimum aperture

and wait until the

delivery pipe is completely free of air.

With a three-phase motor make sure
the direction of rotation is correct.

For this purpose, with the gate valve at half-open
aperture position, check the pressure (with the
pressure gauge) or flow rate (sight check) after
starting. Switch off power, reverse the connections
of two phases on the control panel, re-start and
check the pressure or flow rate capacity again.
The correct direction of rotation will provide a con-
siderably greater and easily distinguishable pres-
sure and delivery capacity.

Make sure the sand residue present in the water
disappeares or is minimal.

Never start or run the pump when the gate
valve has been opened too widely.
Make sure the pump operates within its rated
limits of performance and that the rated absor-
bed current is not exceeded.

Otherwise, regulate the delivery gate valve or the
setting of any pressure switches.

ATTENTION: avoid long periods of operation
with closed discharge.

5.1. Generator supply

The switching sequence is of utmost importance.
If you do not apply this correctly, both motor and
generator may be damaged.
Therefore:
- AIways switch the generator on and off without load!
This means:
- Starting: aiways switch the generator ON first -

and the motor afterwards!

- Stopping: always switch the motor OFF first -

and the generator afterwards!

6. Maintenance

Under normal operating conditions with clean
water the pump will not require maintenance.
Absorbed current and head supplied by the pump
must be checked at regular intervals.
This procedure should be carried out frequently
when water contains considerable quantities of sand.
In the case of emergency systems, it is advisable to
operate the pumps once a month in order to avoid
the risk of blocking and to maintain and verify per-
fect efficiency.

Disconnect electrical power
before any servicing
operation.

Changes reserved.

4.93.128/3

BLACK      1

GREY

       2

BROWN    3

GREEN/YELLOW

M

1

1

Electrical diagram 
single-phase motors

5

Summary of Contents for SD Series

Page 1: ...8 DN 200 10 DN 250 SD SDF SDN SDX SDS ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano ORIGINAL OPERATING INSTRUCTIONS Page 4 English ORIGINAL BETRIEBSANLEITUNG Seite 6 Deutsch INSTRUCTIONS ORIGINALE...

Page 2: ...umulo di sabbia o fango attorno al motore con conseguente pericolo di surriscaldamento Nella tubazione di mandata installare un indicatore di pressione Manometro 4 una valvola di ritegno ad una distan...

Page 3: ...vviare la pompa con saracinesca aperta al minimo e attendere che la tubazione di man data si liberi completamente dall aria Con alimentazione trifase verificare che il senso di rotazione sia corretto...

Page 4: ...d or mud around the motor and to elimi nate the risk of overheating The following components must be installed in the delivery pipe a pressure gauge a check valve at max 7 m from the pump outlet and m...

Page 5: ...the gate valve regula ted to minimum aperture and wait until the delivery pipe is completely free of air With a three phase motor make sure the direction of rotation is correct For this purpose with t...

Page 6: ...ch weder Sand noch Schlamm um den Motor ansammeln und damit eine berhitzung verursacht werden k nnte In der Druckleitung sind zu installieren ein Druckme ger t Manometer 4 Ein R ckschlagventil um ein...

Page 7: ...etr gt 1 Sekunde 5 Inbetriebnahme ACHTUNG Die Pumpe darf keinesfalls trocken betrieben werden auch nicht probeweise Pumpe mit minimal ge ffnetem Absperrschieber starten und warten bis die Druckleitung...

Page 8: ...suffi sante du fond du puits pour viter des d p ts de sable ou de boue autour du moteur et ou toute surchauffe du moteur Dans la tuyauterie de refoulement il y aura lieu d installer un indicateur de p...

Page 9: ...te L ouverture de la vanne doit tre au minimum Attendre l vacuation compl te de l air de la tuyauterie de refoulement En cas d alimentation triphas e v rifier le sens de rotation Pour ce faire fermer...

Page 10: ...secuente peligro de recalentamiento En las tuber as de impulsi n instalar un indicador de presi n Man metro 4 una v lvula de retenci n a una distancia m xima de 7 m de la boca de impulsi n y m s v lvu...

Page 11: ...hacer pruebas Arrancar la bomba con la compuerta abierta al m nimo y controlar que la tuber a de impulsi n quede liberada completamente de aire Con alimentaci n trifasica comprobar que el sentido de r...

Page 12: ...ets slut f r att undvika att sand kommer in i pumpen och f r att elmotorn skall f tillr cklig kylning F ljande komponenter skall installeras i tryckledningen En manometer En backventil max 7 m fr n pu...

Page 13: ...kort stund Starta pumpen med tryckventilen delvis ppen och v nta tills tryckledningen r fri fr n luft Vid trefasinstallation skall rotationsriktningen av elmotorn kontrolleras F r detta ndam l skall t...

Page 14: ...veau komt Plaats de pomp zover van de bodem van de bron dat nodig is om opeenhoping van zand en mod der rondom de motor te vermijden en het risico van oververhitting te verlagen De volgende onderdelen...

Page 15: ...wacht totdat de per sleiding volledig luchtvrij is Bij een drie fase pomp dient de draairi chting gecontroleerd te worden Hiertoe dient men de persklep te sluiten en het drukniveau moet gecontroleerd...

Page 16: ...m3 50 g m3 SDX 25 C 35 C 4 20 4 15 6 8 10 10 2 2 K S SD D 6 6S SD DX X K 3 1 2 7 max 5 50 0 5 2 2 1 1 v 0 08 m s 4 0 16 m s 6 0 2 m s 8 10 3 3 4SD I O 1 2 4 5 6 7 8 10 11 12 13 9 A Z Y X 3 4 93 128 1...

Page 17: ...4 4 3 mm S SD DM M 11 kW 4 4 1 1 4 4 2 2 30 z 60 z 0 30 z 30 0 Hz 1 5 5 5 5 1 1 6 6 K 4 93 128 3 M 1 1 17 K 1 2 3 4 10Nm 4...

Page 18: ...DX 25 C 35 C 4 20 4 15 6 8 10 10 2 0 3 4 4 5 4 SD 6SDX 3 3 0 1 4 7 5 50 0 6 0 5 2 1 7 0 3 v 0 08 4 0 16 6 0 2 8 10 7 0 3 3 4SD 18 1 2 3 4 5 6 7 8 9 10 11 12 13 A Z 100 Y 1 X 1 I O 1 2 4 5 6 7 8 10 11...

Page 19: ...10Nm 4 4 5 5 7 5 7 3 0 4 3 SDM 11 Y 4 1 4 2 5 4 30 F 60 F 0 30 F 30 0 F 1 5 3 5 7 0 4 0 G 3 5 4 0 5 4 4 0 4 4 4 5 3 4 4 4 5 1 3 6 7 5 7 7 0 5 3 19 4 93 128 3 M 1 1...

Page 20: ...SD SDF SDN SDX SDS 1 2 3 4...

Page 21: ...21...

Page 22: ...Only for types Nur f r baugr en Seulement pour les types Solo en los tipos Endast typ 4SD 15 2 64 15 2 64 13 12 03 26 10 64 26 64 19 1 64 19 1 12 31 12 02 64 18 32 02 96 09 15 70 15 50 70 19 14 02 99...

Page 23: ...36 60 4SDF 46 42 4SDF 46 55 4SDF 54 40 4SDF 54 48 4SDF 54 55 96 09 15 70 15 50 70 19 12 03 12 06 12 10 12 16 26 00 28 00 64 13 26 02 26 00 28 00 26 02 64 26 64 18 4SDF22 4SDF36 64 14 64 26 12 01 99 0...

Page 24: ...64 00 64 22 64 24 12 02 28 04 28 08 28 07 64 10 64 15 26 10 26 00 28 00 14 02 26 10 26 00 28 00 26 02 64 14 96 00 99 00 15 50 96 09 70 20 12 04 12 12 12 10 12 01 10 16 6SDN 12 16 21 12 04 12 10 12 01...

Page 25: ...34 02 12 01 12 10 28 04 64 10 28 02 26 00 12 03 26 01 14 54 64 00 64 22 96 04 96 09 25 06 12 12 34 02 12 03 28 00 12 31 64 14 15 50 14 03 6SDX 13 18 27 6SDX 45 60 8SDX 78 97 25 06 12 10 25 06 96 04 9...

Page 26: ...30 25 04 32 02 25 06 96 04 96 09 96 08 15 20 15 50 28 02 28 20 28 20 64 00 64 20 46 50 64 22 64 25 90 00 70 20 99 00 15 20 96 09 3 94 000 64 20 15 50 25 04 14 54 28 00 12 01 12 10 12 12 12 06 25 04 2...

Page 27: ...15 50 25 04 14 54 28 00 12 01 13 13 13 12 13 13 12 10 12 12 12 06 25 04 25 06 25 06 25 02 25 04 25 02 12 30 12 30 28 24 96 04 96 09 96 08 25 06 32 02 28 02 64 00 64 22 64 25 90 00 70 20 99 00 12 30 1...

Page 28: ...50 Strainer 25 02 Stage casing 25 04 Gasket 25 06 Screw 26 00 Diffuser pump 26 02 Diffuser plate 26 08 Diffuser sleeve 26 10 Conveyor ring 28 00 Impeller 28 02 Counter thrust bearing ring 28 04 Impel...

Page 29: ...lo 26 00 Difusor bomba 26 02 Disco del difusor 26 08 Camisa del difusor 26 10 Anillo 28 00 Rodete 28 02 Anillo contra empuje 28 04 Tuerca fijaci n rodete 28 05 Anillo de seguridad 28 07 Arandela fijac...

Page 30: ...30...

Page 31: ...llet i overensstemmelse med bestemmelserne i Direktiv 2004 108 EC 2006 42 EC 2006 95 EC og er i overensstemmelse med de heri indeholdte standarder D F E DK CALPEDA S p A intygar att pumpar SD SDM SDN...

Page 32: ...39 0444 476476 Fax 39 0444 476477 E mail info calpeda it www calpeda it CONSERVARE QUESTE ISTRUZIONI SAVE THESE INSTRUCTIONS DIESE BETRIEBSANLEITUNG AUFBEWAHREN GARDER LA PRESENTE NOTICE CONSERVAR EST...

Reviews: