Hardness:
<120 ppm (120 mg/L) – if hardness level is 120 ppm or slightly below the
quartz sleeve must be cleaned periodically in order to ensure efficient UV
penetration; if above the water must be softened with a Calmag water
softener
Iron (Fe):
<0.3 ppm (0.3 mg/L)
Manganese (Mn):
<0.05 ppm (0.05 mg/L)
Turbidity:
< 1 NTU
Tannins (organics):
<0.1 ppm (0.1 mg/L)
UVT (transmittance):
>85% (Please contact CALMAG YORKSHIRE LIMITED if the water has a UVT
that is less than 80% for pre-‐treatment recommendations)
You can have your water tested at a private analytical laboratory or contact your local council for advice in regards
to your local environmental health officer. It is always recommended to install pre-‐filtration of at least 5 microns
prior to a CALMAG YORKSHIRE LIMITED UV disinfection system. CALMAG YORKSHIRE LIMITED provides pre-‐filters
housings and cartridges as standard on the CALULTRA 12 and CALULTRA 22 units and do recommend pre-‐filters on
all units. Please call to discuss the appropriate filter for the unit.