background image

21   |   

P a g e

   

   

   

Limited   Warranty   Statement   

   

Products   manufactured   by   CALMAG   YORKSHIRE   LIMITED   are   warranted   to   the   original   user   only   to   be   free   of   
defects   in   material   and   workmanship   for   a   period   as   specified   below.   This   warranty   only   applies   to   the   original   
purchaser   and   is   not   transferable.   

UV   SYSTEMS   

Five   (5)   year   Limited   Warranty   on   the   stainless   steel   units,   from   the   date   of   original   purchase,   or   
installation   (documentation   required   for   verification).   

ELECTRONICS   

One   (1)   year   Limited   Warranty   on   the   ballasts   and   controllers,   from   the   date   of   original   purchase,   or   
installation   (documentation   required   for   verification).   

UV   LAMPS,   UV   SENSORS   &   QUARTZ   SLEEVES   

One   (1)   year   Limited   Warranty   on   all   CALMAG   YORKSHIRE   LIMITED   ultraviolet   lamps,   UV   sensors   and   
quartz   sleeves   from   the   date   of   original   purchase   (documentation   required   for   verification).   

CALMAG   YORKSHIRE   LIMITED   warrants   that   it   will   repair   or   replace,   at   CALMAG   YORKSHIRE   LIMITED’s   sole   
discretion,   any   ultraviolet   system   or   component   that   is   defective   in   materials   or   workmanship   for   the   period   as   
outlined   above,   subject   to   the   “Limitations   of   Warranty”   as   outlined   below.   CALMAG   YORKSHIRE   LIMITED's   liability   
under   this   warranty   shall   be   limited   to   repairing   or   replacing   at   CALMAG   YORKSHIRE   LIMITED's   discretion,   without   
charge,   any   product   that   CALMAG   YORKSHIRE   LIMITED   manufactures.   CALMAG   YORKSHIRE   LIMITED   will   not   be   
liable   for   any   costs   of   removal,   installation,   transportation,   or   any   other   charges   which   may   arise   in   connection   
with   a   warranty   claim.   Products   which   are   sold   but   not   manufactured   by   CALMAG   YORKSHIRE   LIMITED   are   subject   
to   the   warranty   provided   by   the   manufacturer   of   said   products   and   not   by   CALMAG   YORKSHIRE   LIMITED’s   
warranty.   CALMAG   YORKSHIRE   LIMITED   will   not   be   liable   for   damage   or   wear   to   products   caused   by   abnormal   
operating   conditions,   accident,   abuse,   misuse,   unauthorised   alteration   or   repair,   or   if   the   product   was   not   installed   
in   accordance   with   CALMAG   YORKSHIRE   LIMITED’s   printed   installation   and   operating   instructions.      

   

LIMITATIONS   OF   WARRANTY      

This   warranty   does   not   apply   to   any   of   the   following:      

 

Water   Quality   Parameters   lie   outside   of   the   following   ranges   

 

Hardness   >   120   mg/L   (7   gpg)   

 

Iron   >   0.3   mg/L   (ppm)   

 

Manganese   >   0.05   mg/L   (ppm)   

 

Tannins   >   0.1   mg/L   (ppm)   

 

Turbidity   >   1   NTU   

 

Transmittance   (UVT)   <   75%   

 

A   product   that   has   been   incorrectly   installed   according   to   the   technical   installation   manual.   

Summary of Contents for CALULTRA 12

Page 1: ...Remember don t guess ASK Calming troubled waters...

Page 2: ...ter supply with a UV system gives you reassurance that your family will have access to safe drinking water throughout your entire home with no chance of microbiological contamination This is chemical...

Page 3: ...on Controller Overview Page 12 Operation Power up Sequence Page 13 Operation Remote Alarm Module Check Page 14 Operation Operational Screens Page 14 Operation UV Intensity Page 15 Operation Lamp Count...

Page 4: ...ed to be installed indoors and away from leaking plumbing DO NOT plug the unit in if the system or any of the components are wet 9 The disinfection system should be directly installed into a ground fa...

Page 5: ...mendations You can have your water tested at a private analytical laboratory or contact your local council for advice in regards to your local environmental health officer It is always recommended to...

Page 6: ...litres per minute it is recommended to install the CALULTRA 79 UV unit There will be occasions where your home is using water at the pump s maximum capacity Location Step 1 Find a suitable location t...

Page 7: ...or so that the rated flow of your particular CALMAG YORKSHIRE LIMITED system is not exceeded and the UV dose is not compromised The flow restrictor should be installed on the outlet port of the unit S...

Page 8: ...P a g e Installation example unit connect ASSEMBLED ring installation unit unit ring unit unit...

Page 9: ...ly and check for leaks Make sure the by pass valves are functioning properly and that the water is flowing through the unit The most common leak is from the O ring not making a proper seal on the unit...

Page 10: ...d Screw Connection Step 17 Your system is now ready to be plugged into the appropriate GFCI protected outlet Plug the unit in and refer to the System Disinfection section before any water is allowed t...

Page 11: ...inlet shut off valve shut this valve off to prevent water flow through the system If there is no inlet shut off valve turn off main water inlet valve and turn of water pump if you have one Step 2 Disc...

Page 12: ...rew counterclockwise the sensor nut from the unit and pull the sensor slowly out of the sensor port Step 6 Holding the sensor in your hand wipe the flat portion sensor face of the sensor with isopropy...

Page 13: ...at the end of 12 months to replace the ultra violet bulb The Calmag Home Screen will then constantly scroll from right to left indicating that the unit is functioning correctly If the controller butt...

Page 14: ...the front of the controller UV Intensity only for units equipped with a UV sensor If your system is equipped with a UV sensor the UV Output screens will indicate the level of UV intensity that is bei...

Page 15: ...he flow of water if a solenoid valve is installed on the system Lamp Countdown Sequence The UV unit counts down the number of days until a lamp change is required The operation is as follows Once the...

Page 16: ...lamp To perform this reset you must firmly depress the button on the front of the controller and then manually plug the power cord back into the wall outlet initiating power to the unit Keep holding...

Page 17: ...Assuming the system has an optional 4 20 mA Module installed if at any time during the operation of the system a 4 20 mA module fails the controller will return both an audible and visual signal indi...

Page 18: ...imply press the control button twice and the QR code screen will appear as follows Expansion Modules As shown earlier in this manual the CalUltra controllers incorporate an Infinite Expandability Port...

Page 19: ...MODULE Allows for a 4 20mA signal transfer of the UV output to a remote device such as a data logger or computer Simply plug the supplied cable into any female IEP connections Two screw terminals are...

Page 20: ...lug Type British Standard BS1363 Lamp Watts 15 22 39 42 Power watts 20 30 49 51 Replacement Lamp BULB B12 BULB B22 BULB B41 BULB B79 Replacement Sleeve SLEEVE QS12 SLEEVE QS22 SLEEVE QS41 SLEEVE QS79...

Page 21: ...mitations of Warranty as outlined below CALMAG YORKSHIRE LIMITED s liability under this warranty shall be limited to repairing or replacing at CALMAG YORKSHIRE LIMITED s discretion without charge any...

Page 22: ...ng the product Any defective product to be returned to CALMAG YORKSHIRE LIMITED must be sent carriage prepaid documentation supporting the warranty claim and or a Goods Return Number must be included...

Page 23: ...23 P a g e...

Page 24: ...24 P a g e Sandbeds Keighley Tel lmagltd com www calmagltd com Remember don t guess ASK Calming troubled waters Rev11 12...