20 |
P a g e
CALMAG YORKSHIRE LIMITED EQUIPMENT
SPECIFICATIONS
CalUltra domestic ultra violet systems
MODEL
CalUltra 12
CalUltra 22
CalUltra 41
CalUltra 79
Flow Rate (@ 16 mJ/cm
2
)
6 GPM
11.0 GPM
20 GPM
39.2 GPM
23 lpm
42 lpm
77 lpm
150 lpm
1.4 m
3
/hr.
2.5 m
3
/hr.
4.6 m
3
/hr.
8.9 m
3
/hr.
Flow Rate (@ 30 mJ/cm
2
)
3 GPM
5.8 GPM
11 GPM
21 GPM
12 lpm
22 lpm
41 lpm
79 lpm
0.7 m
3
/hr.
1.3 m
3
/hr.
2.5 m
3
/hr.
3.6 m
3
/hr.
Flow Rate (@ 40 mJ/cm
2
)
2.4 GPM
4.4 GPM
8.2 GPM
16 GPM
9.1 lpm
17 lpm
31 lpm
59 lpm
0.5 m
3
/hr.
1.0 m
3
/hr.
1.9 m
3
/hr.
3.6 m
3
/hr.
Port Size
½" MNPT
¾" MNPT
¾" MNPT
1" MNPT
Electrical
230-‐240V./50-‐60Hz.
Plug Type
British Standard, BS1363
Lamp Watts
15
22
39
42
Power (watts)
20
30
49
51
Replacement Lamp
BULB-‐B12
BULB-‐B22
BULB-‐B41
BULB-‐B79
Replacement Sleeve
SLEEVE-‐QS12
SLEEVE-‐QS22
SLEEVE-‐QS41
SLEEVE-‐QS79
Unit Dimensions
2.5 x 13.5"
(6.4 x 34.2 cm)
2.5 x 20.5"
(6.4 x 52.2 cm)
2.5 x 34.3"
(6.4 x 87.2 cm)
3.5 x 36.1"
(8.9 x 91.7 cm)
Chamber Material
Polished 304 Stainless Steel, A249 Pressure Rated Tubing
Controller Dimensions
6.8 x 3.6 x 3" (171.5 x 92.1 x 76.2 mm)
Maximum Operating
Pressure
8.6 bar (125 psi)
Optimum Water
Temperature
2-‐40° C (36-‐104° F)
UV Monitor Port
(upgradeability)
No
Yes
Solenoid Output
Yes, but requires optional solenoid module (see page 19)
4-‐20 mA Output
Yes, but requires optional 4-‐20 mA module (see page 19)
Lamp Change Reminder
(audible & visual)
Yes
Lamp-‐Out Indicator
(audible & visual)