Operational Screens
On the Calmag domestic systems (without the UV monitor), the default screen shows the CALMAG YORKSHIRE
LIMITED Home Screen. At any point during the operation the user is able to scroll through the CALMAG
YORKSHIRE LIMITED Home Screen and Lamp Life remaining screen by simply pressing the button located on the
front of the controller.
% UV Intensity (only for units equipped with a UV sensor)
If your system is equipped with a UV sensor the % UV Output screens will indicate the level of UV intensity that is
being detected within the unit by the sensor. This will always be visible on the Home Screen of the controller.
Things that can affect the % UV Output are poor water quality, scaling of the quartz sleeve and/or sensor, lamp
failure, expired lamp life and sensor failure. The following screens show the % UV Output dropping on a monitored