ACCESSORY WIRING
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01
PAGE 30
Most accessories can be wired into the relay input.
Use OPEN/LOOP for Normal Open (N/O). Use Relay for Relay.
Use the CLOSE Input for Normal Close (N/C).
If Using the gate operator to power the accessory, use 24_VDC and the 24V-COM input
Solenoid / Electric Lock
Ver.3.1 Circuit Board: Use the SOL-LOCK input.
Ver.3.0 Circuit Board and below: Use the MOTOR1 and MOTOR2 terminal.
MagLock
Ver.4.2 Circuit Board: Use the MAGLOCK input and turn dip switch #7 (Labeled “MAGLOCK”) to ON
Push To Exit Button
Normal Open (N/O) - OPEN/LOOP
Normal Close (N/C) - CLOSE
If using the gate operator to power the accessory, use 24-VDC and the 24-COM input
FIGURE A -
Exit Loop Terminals
Located on the right side of the board
Commonly Used For:
1. Reverse/Phantom/Exit Loops
2. Electric Locks
3. Fire Access Box
FIGURE B -
Relay Terminals
Located on the top right side of the circuit board mounting panel
Commonly Used For:
1. Intercoms / Access Controllers
2. Keypads
FIGURE C -
Monitored Terminals
Located on the top right side of the circuit board mounting panel
Commonly Used For:
1. Photocell Sensors
2. Safety Edges