By default, the included remote controls are already connected to the gate operator. You do not need to do
any of the following steps unless you are adding more remote controls to your system.
This gate operator can add up to 50 different remote control. to add more than 50 controls, you need to add
an addition reciever, which can add up to 100 additional remote controls. Calimet remote controls use 418
MHz frequency with a 300’ max distance. there are two ways to connect: Learn and Dip Switch.
Program by Learn (CM9-864, CM9-510, CM9-510B)
Connect Using Learn
- On your gate operator circuit board, look for the learn button. Press and hold the
LEARN/STUDY button until the flashing light turn solid, about 2 sec. Then release and immediately press
and hold the button on the remote control. Release until LEARN/STUDY light flashing again. Your remote
is now connected with your gate operator.
Remove All Existing Remote Control
- Press the LEARN/STUDY buttoon on the gate operator circuit board
and hold for 8 seconds (The light pattern is flashing - solid - flashing) then release. All remote controls are
now removed.
Program by Dip Switch (CM9-509)
1. On your circuit board find the 1-8 Dip Switch, turn the nearby OFF/ON switch to ON.
2. Unscrew the back of the remote control to gain access to the control circuit board. your should see 1-8
dip switches. each switch has 3 positions: UP, MIDDLE, and BOTTOM. Flip these 1-8 switches to any
random position to created your own code (FIGURE A).
3. On the gate opener circuit board, set the same 1-8 dip switch combination as you did on the remote. your
remote is not connected to the gate opener.
NOTICE - Do not share your dip switch code and keep it safe. Anyone have access to your code will have
access to your gate system.
REMOTE CONTROLS
CM9-2 INSTALL ATION AND OWNER MANUAL V.3.1 | 2023.06.01
PAGE 26
FIGURE A
DIP
DIP