povm
r/o
uW
of each slot
lnvm
r/o
[card1],..,[card20]
mA
LNB current for each slot
tmpm
r/o
[temp1],[temp2] °
C
Temperature chassis
Fault related commands
name
range/format
description
alrm
r/o
[see below]
Faults chassis
HTTP Only Setup related commands
name
range/format
description
sdes
r/o
SNMP System description
scon
r/w
SNMP System contact
snam
r/w
SNMP System name
sloc
r/w
SNMP System location
rcom
r/w
SNMP read community
wcom
r/w
SNMP write community
tcom
r/w
SNMP trap community
autr
r/w
enabled,disabledSNMP enable Auth traps
refr
r/o
1,3,5,10
Refresh Rate (secs)
clft
o/w
1
Clear latched faults
Fault Message
The commands 'alrm' return a text string which shows the fault status of the master or slave
chassis.
Syntax: S[power supply faults]R[rf faults]O[optical faults]L[lnb faults]T[threshold faults]S[switch
fault]C[internal fault]
The power supply faults list contains 2 characters for power supply 1 to 2. The rf faults , optical
faults , lnb faults , threshold faults and switch faults lists contains 20 characters, representing the
20 slots of a sat-nms LFTXRX chassis. The internal fault shows that there is a problem with the
internal communication between different components of the sat-nms LFTXRX chassis.
The meaning of the fault characters are: 0 means OK and 1 means FAULT.
http://192.168.2.81/rmt?alrm=?
alrm=
S10
R00001000010000000000
(C) 2021, SatService GmbH
www.satnms.com
LF20-UM-2107 Page 36/43