![background image](http://html1.mh-extra.com/html/caleffi/7200-series/7200-series_operating-steps-installation-manual_3387609003.webp)
3
During the inspection it is essential to establish which mounting kit is suitable for the type of heating body on which the heat cost allocator is to
be fitted.
See Table 1 on pages 11-12 to choose the suitable kit.
Example:
- Heat emitter:
CAST IRON PLATES
- Distance between the elements:
LESS THAN 4 mm
- Mounting kit:
code 720060
D
D
D
Cast iron plates
7200
60*
7200
61*
4
4
L
Distance between elements (D)
less than or equal to 4 mm
Distance between elements (D)
from 4 to 10 mm
plate (39 mm) + anchor (20 / 39 mm)
plate (39 mm) + anchor (59 mm) + anchor (75 mm)
plate (55 mm) + anchor (20 / 39 mm) + anchor (59 mm)
plate (55 mm) + anchor (75 mm)
plate (88 mm) + anchor (39 mm)
plate (88 mm) + anchor (59 mm) + anchor (75 mm)
plate (88 mm) + anchor (75 mm) + screws (M4 x 130 mm)
plate (39 mm) + self-tapping screw
plate (39 mm) + threaded plate
plate (39 mm) + welded stud bolts
plate (39 mm) + expanding corner pieces
Code
Description
7200 Mounting kit
7200
50
7200
51
7200
52
7200
53
7200
54
7200
55
7200
56
7200
60
7200
61
7200
62
7200
63
N.B. When ordering the mounting kit, check that the number of pieces is a multiple of the minimum pack.
IMPORTANT:
The tightening torque of the screws used in the mounting kit must be between 0.8 and 1 N
·
m.
1. PRELIMINARY INSPECTION (to be carried out by the installer)
No. of items in the pack
5
5
5
5
5
1
1
5
5
5
1