Parameterisation (to be carried out by the installer) comprises the following services:
• In situ heat cost allocator parameterisation.
• Radio transmission functional test.
Parameterisation means programming the heat cost allocator with the power value (
D
T 60°C) according to the actual dimensions and
characteristics of the heating body on which it is installed.
Parameterisation, in case of domestic hot/cold water pulse acquirers, means programming the characteristic coefficient K (litres/pulse) of the
volume meter to which the device is connected. It is besides possible to match the count of the pulse acquirer with the one of the volume meter.
This data is necessary for proper metering of the heat consumption by the heat cost allocators which are programmed by means of the
USB/radio device (code 720090) and the software provided.
Normally, parameterisation is done in one go when installation has been completed and the mapping data of the specific building (see pages
15 - 16) has been entered in the SW7200 software.
3. COMMISSIONING – PARAMETERISATION
4. HEAT COST ALLOCATOR CONSUMPTION READOUT PROCEDURES
MONITOR 2.0 - 2.0 E - 2.0 PULSE
Consumption is read (by the condominium person in charge) using a laptop PC with Microsoft
®
Windows operating system, the USB/radio
device (code 720090) and the SW7200 software provided, which allow reading, displaying consumption and creating reports.
A user guide for proper use of the software is provided
5
L · 0,
L
502
mbar
300
350
400
450
500
550
600
0
4
0,5
1
1,5
2
2,5
3
3,5
4
502
mbar
300
350
400
450
500
550
600
0
4
3
2
1
0
0,5
1
1,5
2
2,5
3
3,5
4
code 720020
code 720025
Laptop PC
Code 720090
Consumption data readouts
by means of the USB to radio device.
code 720030