background image

20

Declaration of conformity

It is hereby declared that the product meets the applicable essential requirements of the R&TTE Directive 1999/5/EC. The CE 0470 marking on the

product and in this document certifies conformity with the Directive. An unabridged copy of the Declaration of Conformity with the R&TTE Directive

1999/5/EEC is available on request at the address below.

CALEFFI S.P.A.

S.R. 229, n. 25

28010 Fontaneto d’Agogna (NO) - Italy

Tel. +39 0322 8491 / Fax +39 0322 863723

Model: 7200

Marking: CE 0470

We reserve the right to make improvements and modifications to the products described and the relative technical data at any time and without prior
notice.

Problem

Likely cause

Suggested solution

Device disconnected from the radiator

Impact or other

Contact a certified installer to have it fastened

Missing seal

Tampering

Contact a certified installer to have it fitted

Position of the device changed since it was

installed

Tampering, impact or other

Contact a certified installer to have it fastened

The display shows the alert code 

FL8888

or 

F

r

8888

The internal self-test has detected a fault

Contact a certified installer and specify the

code 

FL8888

or 

F

r

8888

Null consumption is shown

No consumption has been logged.

This is not a fault. If the radiator is off, no energy

emission is detected. In case the volume meter is

replaced the count of the device must be reset.

Low consumption is shown

Beginning of a new season

(heat cost allocator only)

This is not a fault. When the season start date

is exceeded shown heat consumption is reset

to zero

Nothing is shown on the display when the

button is pressed

Internal problem

Contact a certified installer to have the device

checked

Warnings for proper disposal of the product

The symbol shown on the side appears on the product MONITOR 2.0/2.0 E/2.0 PULSE to indicate that this product may not

be disposed of as household waste.

This means that the European Directive on waste electrical and electronic equipment (WEEE) applies and that the product

must therefore be sent to differentiated waste collection centres.

Moreover, the national laws on waste equipment collection systems need to be complied with.

TROUBLESHOOTING 

Summary of Contents for 7200 Series

Page 1: ...of heat consumption are performed obtaining improved comfort quantification of the actual heat consumption and a fair allocation of costs The heat consumption data can be collected via radio and proce...

Page 2: ...tion 35 code 720050 Kit Table 1 on pages 11 12 32 code 720020 MONITOR 2 0 heat cost allocator 32 code 200000 Thermostatic control head for radiator valves Code 720050 comes in a minimum 5 piece pack a...

Page 3: ...r 75 mm plate 55 mm anchor 20 39 mm anchor 59 mm plate 55 mm anchor 75 mm plate 88 mm anchor 39 mm plate 88 mm anchor 59 mm anchor 75 mm plate 88 mm anchor 75 mm screws M4 x 130 mm plate 39 mm self ta...

Page 4: ...ed during installation 4 Display selection button 5 Retaining screws tightening torque 0 8 1 N m 6 Aluminium thermal coupling plate 7 Fastening brackets 1 Anti tampering seal 2 Heat cost allocator com...

Page 5: ...downward STEP 3 Press down on the bottom part of the heat cost allocator until it is securely in place a b a b MONITOR 2 0 MONITOR 2 0 E 2 0 PULSE MONITOR 2 0 2 0 E 2 0 PULSE a b 2 INSTALLATION AND M...

Page 6: ...st to the valve Cut off the excess part using cutting nippers as it may damage the device YES NO The heat cost allocator positioning indicator must ALWAYS be positioned exactly at 75 1 cm of the heigh...

Page 7: ...ed exactly at 75 1 cm of the development of the coil or at 50 1 cm of the height in the case of a single block convector 2 INSTALLATION AND MAPPING to be carried out by the installer MONITOR 2 0 E wit...

Page 8: ...e volume meter to the device inputs with screw terminals Figure A as illustrated in the picture below Positioning the consumption data acquisition device In order to guarantee correct operation of the...

Page 9: ...s smooth columns Material Type Description UNI 10200 type Small columns Section 30 x 30 mm Large columns Section 30 x 30 mm hub 50 mm hub 55 mm hub 55 mm hub 60 mm A B C D Columns joined by diaphragm...

Page 10: ...st allocator serial number MONITOR 2 0 2 0 E Radiator cover S shelf distance 15 cm C full cover S C C C C C C KITCHEN LIVING ROOM MASTER BEDROOM BATHROOM HALL H mm W mm D mm 2 0 E 2 0 E 2 0 E 2 0 E 2...

Page 11: ...etween elements D less than or equal to 35 mm Distance between elements D from 36 to 45 mm 720051 720053 Minimum 5 piece pack 4 4 Distance between elements D less than or equal to 4 mm Distance betwee...

Page 12: ...tubes 720062 Smooth surface Lamellar radiators Lamellar Lamellar 720063 Towel warmer Horizontal tubes 720050 Distance between elements D from 24 to 28 mm D 24 D 28 Towel radiator MOUNTING KIT MOUNTING...

Page 13: ...t coil Double or triple element without coil Single double or triple element with coil Coil convector Single fin convector Single block convector mounting kit included in the heat cost allocator pack...

Page 14: ...columns Highly finned Averagely finned Lightly finned Plate without fins With rear fins With fins between the plates Vertical or horizontal tubes G H I L M N O P Cast iron or steel Bare tube Cast iron...

Page 15: ...Denomination No of buildings No of dwellings No of radiators No of towel warmers radiators No of conv ectors No of MONITOR 2 0 heat cost allocators No of MONITOR 2 0 E heat cost allocators Address Nam...

Page 16: ...which condominium dwelling and room they correspond RADIATOR CONVECTOR 1 1 If convectors are present it is necessary to fill the Installed capacity W field 6 T 60 C TOWEL RADIATORS 2 DOMESTIC HOT COLD...

Page 17: ...ogrammed by means of the USB radio device code 720090 and the software provided Normally parameterisation is done in one go when installation has been completed and the mapping data of the specific bu...

Page 18: ...RESET Reset date li57 ba FW VERSION INSTALLED Shows the firmware version installed OTHER MESSAGES DIFFERENT FROM THOSE LISTED ABOVE ARE STRICTLY FOR QUALIFIED TECHNICAL PERSONNEL 88 88 88 EXXXXX FXXX...

Page 19: ...MPTION First 4 digits of the total consumption of the previous year PREVIOUS PERIOD CONSUMPTION Last 4 digits of the total consumption of the previous year PREVIOUS YEAR CONSUMPTION LOGGING DATE Day m...

Page 20: ...have it fastened The display shows the alert code FL8888 or Fr8888 The internal self test has detected a fault Contact a certified installer and specify the code FL8888 or Fr8888 Null consumption is...

Reviews: