![CALEFFI 7200 Series Operating Steps - Installation Manual Download Page 9](http://html1.mh-extra.com/html/caleffi/7200-series/7200-series_operating-steps-installation-manual_3387609009.webp)
9
2. INSTALLATION AND MAPPING (to be carried out by the installer)
MONITOR 2.0 - 2.0 E (remote probe)
800
600
120
10
F
Room
Heat cost allocator serial number
MONITOR 2.0 - 2.0 E
Radiator cover
S = shelf
(distance < 15 cm)
C = full cover
Dimensions
S
C
C
C
C
C
C
KITCHEN
LIVING ROOM
MASTER BEDROOM
BATHROOM
HALL
(*) H (mm)
W (mm)
D (mm)
2.0 E
2.0 E
2.0 E
2.0 E
2.0 E
2.0 E
CHILDREN’S BEDROOM
(*) H means the height of the radiator and
NOT
the distance between hub centres
No. of
elements
Type
UNI 10200
See Table 2
Example: A
Installed
capacity (W)
Δ
T
60°C
Tick if the heat
cost allocator
is with remote
probe
(
MONITOR 2.0 E)
Brand
Series
Model
Type
EN 442
S
S
S
S
S
2
1
3 4 5 6 7 8
x
C
2.0 E
S
(2)
If you do not have the brand-name, series and model of the towel warmer or radiator, you need to send an e-mail to the address
attaching a
photo
and indicating the
tube and manifolds diameters
and to which condominium, dwelling and
room they correspond.
RADIATOR / CONVECTOR /
(1)
(1) If convectors are present it is necessary to fill the “Installed capacity (W) field.
Δ
T 60°C”
TOWEL RADIATORS
(2)
Example of data entry for a radiator using UNI 10200:
1
2
3
6
7
8
4
5
UNI 10200 type (see Table 2):
EXAMPLE: Heating body: cast iron plates, smooth columns
Material
Type
Description
UNI 10200 type
Small columns
Section < 30 x 30 mm
Large columns
Section > 30 x 30 mm
hub
*
50 mm
hub
*
55 mm
hub
*
55 mm
hub
*
60 mm
A
B
C
D
Columns joined by diaphragm
E
Smooth columns
F
Finned columns
Highly finned
Averagely finned
Lightly finned
Plate without fins
With rear fins
With fins between the plates
Vertical or horizontal tubes
G
H
I
L
M
N
O
P
Cast iron or steel
Bare tube**
Cast iron plates
Aluminium
Steel
Cast iron or steel
Hub means the following dimension:
*
Bare tube means tubing visible in the rooms.
**
D + 23
D + 23
D
Room
Enter the room where the heating body is installed.
Heat cost allocator serial
number
Enter the serial number
indicated on the label on
the top part of the heat
cost allocator.
Radiator cover
Indicate whether the radiator has a shelf cover S
only if its distance from the radiator is less than 15 cm
or a full cover
C
(tick ONLY if the radiator has a shelf or a full cover).
Dimensions
Specify the
dimensions of the
heat emitter
expressed in mm
.
H = height
W = width
D = depth
No. of elements
Enter the number of elements the radiator is made of.
Convector. Installed capacity (W)
Where there are convectors, it is essential to indicate the installed capacity referring to
D
T 60°C.
MONITOR 2.0 E heat cost allocator with remote probe
Tick ONLY if the heat cost allocator is fitted with a remote probe (MONITOR 2.0 E).
H
W
D
1
2
3
4
5
6
7
8
Mapping
Mapping means filling the condominium and apartment survey sheets (see pages 15-16)