Operating Your Spa
2006 Portable Spa Owner's Manual
Page 23
LTR20061000, Rev. A
Automatic Time outs
These features will automatically turn themselves off during periods of continuous use:
•
Low speed pump
After 4 hours
•
High
speed
pumps
After
15
minutes
•
Optional circulation pump After
15
minutes
•
Optional
turbo
After
15
minutes
•
Spa
light
After
15
minutes
Setting Filtration Cycles
Your spa is programmed to filter twice a day. The first cycle will begin 6 minutes after the spa is turned on and
the second cycle 12 hours later. The factory has programmed the cycle to last for 2 hours but this can be
switched to 4, 6, or 8 hours depending on your requirements. To set filtration time, turn off the power to the spa
at the time of day you would like one of the filtration cycles to begin then turn back on after 30 seconds. When
power has been restored, press the “Temp” button then the “Jets” button. Press “Temp” button again to change
the filtering cycle duration. When desired duration is selected press the “Jets” button to exit.
At the beginning of each filtering cycle the Turbo system will run for approximately 30 seconds. The low speed
pump will run for the duration of the filtering cycle and if an Ozone system is installed it will be activated.
During filtering, “FC” will appear on the main display.
Diagnostic Messages
Message Meaning
--
Spa temperature is unknown. After pump has been running for 2 minutes temperature
will be displayed.
HH
Overheat protection (spa is shutdown)
DO NOT ENTER THE WATER!
One sensor
has detected 118˚F (48˚C) at the heater. Remove the spa cover and allow spa to cool
below 107˚F (42˚C). Press any button on the topside display to reset spa. If spa will not
reset after spa has cooled, turn off power for approximately 30 seconds and then turn
power back on. If display message is repeated then shut the power off to the spa and call
your dealer or service organization.
OH
Overheat protection (spa is shutdown)
DO NOT ENTER THE WATER!
If the spa has
reached 110˚F (43˚C), remove the spa cover to cool the water. At 107˚F (42˚C), the spa
should reset itself. If the spa does not reset, then shut the power off to the spa, wait 30
seconds and restore power to spa. If display message is repeated then shut the power off
to the spa and call your dealer or service organization.
IC
A possible ice condition exists within the spa. No action is required, the pump will
automatically activate.
SA or Sb
Spa is shut down. Spa has detected that one of the sensors is not operating properly. One
of these may display briefly during overheat then disappear when overheat situation has
been resolved. Call your dealer or service organization if message does not go away.