Operating Your Spa
2006 Portable Spa Owner's Manual
Page 33
LTR20061000, Rev. A
To unlock the panel:
•
Press “TIME”, “JETS 1” then the “DOWN” button within three seconds.
Setting the Temperature Lock
To activate the temperature lock:
•
Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, then the “UP” button within three seconds. The
panel will display “TEMP LOCK” when the set temperature is locked.
To unlock the set temperature:
•
Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, and then the “DOWN” button.
Circulation Pump
This is an optional feature. The circulation pump will come on when the system is checking temperature, during
filter cycles, during freeze conditions, or when another pump is on.
Preset Filter Cycles
There are two filter cycles per day. The start and end times of each cycle are programmable. To program, set the
time as instructed above, then press “MODE/PROG” to advance to the next setting (or to exit after the last
setting). The default filter cycles are as follows:
•
The first filter cycle is automatically activated at 8:00 AM and operates the pump until 10:00 AM. The
“FILTER 1” indicator icon will light when filter 1 is running.
•
The second filter cycle is automatically activated at 8:00 PM and operates the pump until 10:00 PM. The
“FILTER 2” indicator icon will light when filter 2 is running.
The pump and the ozone generator will run during filtration. At the start of each filter cycle, the blower will run
on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run
for five minutes. In the event of power loss or shut down, the time of day will need to be reset for filter cycles to
run according to your desired programming.
Clean-up Cycle
When the pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or
blower is turned off or times out. The pump and the ozone generator will run for one hour.
Ozone
This is an optional feature. On most systems, the ozone generator (if installed) runs during filter cycles (except
when pump 1 is operating at high speed on a non-circ system) and during clean-up cycles. On some systems,
the ozone generator operates whenever the pump runs. If your system is configured with the optional ozone
disable feature, the ozone generator will turn off for one hour any time a function button (“JETS 1”, “JETS 2”,
“OPTION” etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 44°F within the heater, the pump automatically activates to provide
freeze protection. The equipment stays on until four minutes after the sensors detect that the spa temperature has
risen to 45°F or higher. In colder climates, an optional additional freeze sensor may be added to protect against
freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts