1.7 System Menu Reference
Press
[Shift]+[P-Set]
(System) to enter into the system menu interface. At this
point, the VFD screen displays the system menu items. Each menu item has a
numbering identifier. The user can press Up and Down buttons or use the knob
for scrolling display of other menu items. Press
[Enter]
on a menu interface to
enter the setting interface. Press
[Esc]
to return to the previous menu. The
instrument return to home-screen automaticly when no action in a long time.
The description of the menu items is shown in the table below.
System
System menu
Beep
Set the beeper state.
Off
Turn the beeper off.
On
Turn the beeper on.
PowerOn
Set the power-on state.
Reset
When the instrument is powered on, the instrument
will initialize some settings and [On/Off] state.
Last
When the instrument is powered on, the instrument
will remain the same settings and [On/Off] state as
last time you turned off the instrument.
Last+Off
When the instrument is powered on, the instrument
will remain the same settings as last time you turned
off the instrument, but the [On/Off] is OFF state.
Sense
Set the sense measurement function
Off
Turn the sense function off.
On
Turn the sense function on.
I/O Config
Select the interfaces communicating with PC and display dynamic
information of different interface card.
None
No optional communication interfaces.
USB+LAN
When insert IT-E1206 communication board into
expansion slot, the menu displays this information.
USB
USB communication interface.
TMC
USB-TMC protocol
VCP
Virtual serial port
LAN
LAN communication interface.
Lan Info
View the LAN information.
Status
IP Mode Status
IP Addr
Sub Net
Copyright © Itech Electronic Co., Ltd.
8