Output Protection range
OCP
-3.1A or 3.1A
OVP
610V
OPP
-810W or 810W
External analog (optional)
Voltage programming
External 0V~10V is 0~600V
Voltage monitoring
External 0V~10V is 0~600V
Current programming
External -10V~10V is -3A~3A
Current monitoring
External -10V~10V is -3A~3A
AC parameters
Voltage range
100VAC -240VAC
OVP
264VAC
UVP
90VAC
Frequency
47Hz~63Hz
Max. current (rms)
4Aac (AC220V)
Power factor PF
>0.98(Lead or Lag)
DC Offset
-0.1A~+0.1A
Harmonic THDI
<5%
Environment
Working temperature
0- 40 °C
Storage temperature
-20- 70℃
Noise
60dB
External temperature measurement
Measurement range
-20℃——120℃
Measurement accuracy
±1℃
Measurement resolution
0.1℃
Efficiency
Max. efficiency (Full-load)
88%
Communication(Optional)
Communication interfaces
RS232/USB/RS485/CAN/LAN/GPIB/Analog
Mechanical parameters
Size and weight
450mm*214mm*43.5mm
Net weight
5kg
Copyright © Itech Electronic Co., Ltd.
137