Setup Resolution
0.1W
Accuracy
<1.0% Pmax
Output Read-back
Read-back current
Range
-30A~30A
Resolution
1mA
Accuracy
<0.1% Imax+0.1%Icurrent
Read-back Voltage
Range
0-60V
Resolution
1mV
Accuracy
<0.1% Umax
Read-back Power
Range
-200W~200W
Resolution
0.1W
Accuracy
<1% Pmax
Temperature Coefficient
Temperature
Coefficient
Voltage Tempera-
ture Coefficient
100ppm/
℃
Current Tempera-
ture Coefficient
50ppm/
℃
Battery Test
AH Measurement
AH Range
0AH-300AH
Accuracy
0.20%
Resolution
0.001AH
Regulation
Load Regulation
Voltage
≤0.05% Umax
Current
≤0.05% Imax
Line Regulation
Voltage
≤0.05% Umax
Current
≤0.05% Imax
Ripple
Ripple
Voltage
≤100mVp-p
Current
≤30mArms
value voltage rise/fall time
Rise time
Voltage(No load)
5ms
Rise time
Voltage(Full load)
10ms
Fall time
Voltage(No load)
5ms
Fall time
Voltage(Full load)
5ms