Power Switch Introduction
The power switch is located in the lower left corner of the front panel. The power
switch is a button, and pressing once indicates
ON
and pressing again indicates
OFF
.
Turning the POWER Switch On
Check that the power cord is connected properly.
Flip the POWER switch to the ( | ) side to turn the instrument on. The front panel
display will light up after a few seconds. It may take about 30 seconds or so for
the power supply to initialize before it is ready for use.
If a self-test error occurs, an error message will be displayed in the front panel.
Press the
[Esc]
button to try to clear the current fault status. The user can also
restart the instrument to try to clear the fault status. Wait until the power is
turned off and then start again. If the problem still cannot be solved after
restarting, please contact the ITECH engineer. Common error messages are
shown in the following table:
Error Messages
Description
Module Init Lost
The module information is lost.
Cal User Data Lose
User calibration information is lost.
Cal Factory Data Lose
Factory calibration information is
lost.
Fan 1 Error!
Fan 1 is abnormal.
Fan 2 Error!
Fan 2 is abnormal.
Chan Number Conflict
The channel number is conflict.
Ms Group Confict
The master group is conflict.
Search Slave
The instrument is searching the
slave.