5
Advanced Function
Battery Charging/Discharging Test Function
5.1 List function
The user can edit the test procedure composed of several steps with the List
function. With List function, a total of 10 List files (List 1~List 10) can be created,
and a maximum of 100 steps (Step 1~Step 100) can be configured for each List
file. The user needs to edit the voltage, current and duration of each step, and
set certain repeated number of times and final state for each List file. List func-
tion menu is as follows.
List
List mode
Run
List function switch
Recall
Recall and view List files
Recall
List=1/
10
Select the number of the recalled List file.
List
Setup
View the attribute parameters of List file, which shall be
consistent with List Setup edited in the Edit. The attribute
parameters can only be viewed and cannot be modified.
View
Step
View the step parameters of List file, which shall be con-
sistent with Edit Step edited in the Edit. The step parame-
ters can only be viewed and cannot be modified.
Edit
Edit List files (List 1~List 10)
Edit
List=1/
10
Select the number of edited List file.
List
Setup
Edit the attribute parameters of List file
Mode
Set the List running priority
mode:
•
CC: Current mode.
•
CV: Voltage mode.
I_Lim +
High limit value of positive
current, which needs to be
Copyright © Itech Electronic Co., Ltd.