 Cable preparation

•  Keep the earth (ground) wire longer than the other wires.

Earth (Ground) 
wire

40 mm

Power supply cable or 
Connection cable

60 mm

 Wiring procedure

(1)  • Remove the tapping screws. (2 places)
 

• Remove the service cover by pushing downwards.

Service cover

Screws

Direction of the 
service cover 
removal

(2)

 

Connect the power supply cable and the connection cable to terminal.

(3)  Fasten the power supply cable and connection cable with cable clamp.

Single phase type

Terminal blocks

Use the speci

fi

 ed 

wire type and 

connect it securely.

Firmly secure cable clamp 

so wire terminations will not receive 

external stress.

Connection cable

Power supply cable

Indoor

unit

Earth 

(Ground)

Three phase type

Terminal blocks

Use the speci

fi

 ed 

wire type and 

connect it securely.

Firmly secure cable clamp 

so wire terminations will not receive 

external stress.

Connection cable

Power supply cable

Indoor

unit

Earth 

(Ground)

(4)  Secure the cables using the cable clamp attached to the base of the valves.

Cable clamp

(5)  Put the service cover back after completion of the work.
 

Replace the tapping screws. (2 places)

Service cover

Direction of the 
service cover 
attachment

9379069953_IM.indb   11

9379069953_IM.indb   11

5/24/2019   9:59:20 AM

5/24/2019   9:59:20 AM

Summary of Contents for AOYG-KQTA

Page 1: ...Children should be supervised to ensure that they do not play with the appliance CAUTION For the air conditioner to work appropriately install it as written in this manual This product must be instal...

Page 2: ...copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the sy...

Page 3: ...issioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed...

Page 4: ...the units are further apart than this correct operation cannot be guaranteed Single type installation Capacity Btu h class 30 000 1 36 000 45 000 54 000 Pipe diameter Liquid Gas Standard mm in 9 52 3...

Page 5: ...rom rain or direct sunlight If the outdoor unit must be installed in an area within easy reach of the general pub lic install as necessary a protective fence or the like to prevent their access Instal...

Page 6: ...ations indicated with arrows in the figure To reduce vibration do not install the unit directly on the ground Install it on a secure base such as concrete blocks The foundation shall support the legs...

Page 7: ...Slit Fig B Fig C 3 5 2 Pipe connection Brazing CAUTION If air or another type of refrigerant enters the refrigeration cycle the internal pressure in the refrigeration cycle will become abnormally high...

Page 8: ...ealing test again 7 After completing the sealing test release the nitrogen gas from both valves 8 Release the nitrogen gas slowly When using conventional flare tools to flare R410A pipes the dimension...

Page 9: ...wires make sure the power supply is off Never touch electrical components immediately after the power supply has been turned off Electrical shock may occur After turning off the power always wait 10...

Page 10: ...l will be displayed and the unit will be inoperable 3 8 1 How to connect wiring to the terminal Caution when wiring cable When stripping off the coating of a lead wire always use a special tool such a...

Page 11: ...connect it securely Firmly secure cable clamp so wire terminations will not receive external stress Connection cable Power supply cable Indoor unit Earth Ground Three phase type Terminal blocks Use t...

Page 12: ...re control will not activate during test operation continuous operation If a knocking sound can be heard in the liquid compression of the compressor stop the unit immediately and then energize the cra...

Page 13: ...cause a serious accident such as electric shock CAUTION Once refrigerant charging is completed be sure to open the valve prior to performing the local settings Otherwise the compressor may fail Discha...

Page 14: ...ing on the operating condition the noise level may not decrease even if the Low noise mode is on Level 2 Blink 9 times 2 Peak cut mode setting Level 1 Blink 9 times The capacity limit can be selected...

Page 15: ...rning to Operation status displays normal operation by pressing the EXIT button once 8 EXTERNAL INPUT AND OUTPUT 8 1 External input 8 1 1 Wiring of connector On Off of the Low noise mode and Peak cut...

Page 16: ...the button on the display board It may cause a serious accident such as electric shock During the pump down operation make sure that the compressor is turned off before you remove the refrigerant pipi...

Page 17: ...ss PUMP DOWN button S130 for 3 seconds or more after 3 minutes after power on POWER MODE ERROR PUMP DOWN LOW NOISE PEAK CUT L1 L2 L3 L4 L5 L6 Sign Lights off Lights on LED display lights on as shown i...

Page 18: ...error Outdoor temp sensor error Blink 2 times Blink 7 times Blink 4 times Heat sink temp sensor error Heat sink temp sensor error Blink 2 times Blink 7 times Blink 7 times Current sensor error Curren...

Reviews: