CAC / BDP EHUMD800ASM00BA Owner'S Manual Download Page 7

- 12 -

- 13 -

BASE LIMITED WARRANTY

Subject to the terms and conditions of this limited warranty, Trane U .S ., Inc . (“Company’) extends a 

limited warranty against manufacturing defects for the product(s) identified in 

Tables 1

1A

1B

 attached 

hereto (“Products’) that are installed in a residential/multi-family application (personal, family or household 

purposes) under normal use and maintenance in the United States and Canada .

This limited warranty applies to Products manufactured on or after January 1, 2017.

In order to maximize the available benefits under this limited warranty, the Purchaser (as defined below) 

should read it in its entirety . All repairs of Product parts covered under this limited warranty must be made 

with authorized service parts and by a licensed HVAC service provider . Additionally, commercial applications 

are treated differently under this limited warranty as stated in 

Tables 1

1A

1B

 attached hereto . For 

purposes of this limited warranty, “commercial applications” shall mean any application other than for 

personal, family, or household use .

TERM:

 The limited warranty period for Products is as stated in 

Tables 1

1A

1B

 attached hereto . If the 

Purchaser properly registers the Products, the limited warranty period shall be extended as stated in 

Tables 

1

1A

1B

 attached hereto . Regardless of registration, the Commencement Date for a limited warranty 

period shall be the date that the original installation is complete and all Product start-up procedures have 

been properly completed and verified by an installer’s invoice . If the installation and start-up date cannot 

be verified by the installer’s invoice, the Commencement Date shall be sixty (60) days after the factory 

manufacture date which is verified by the Product serial number . Where a Product is installed in a newly 

constructed home, the Commencement Date is the date the Purchaser purchased the residence from the 

builder .

Proof of Product purchase, installation, and/or closing date of the residence may be required to confirm 

the Commencement Date .

The installation of Product replacement parts under this limited warranty shall not extend the original 

warranty period . The warranty period for any Product part replaced under this limited warranty is the 

applicable warranty period remaining under the original Product warranty .

WHO IS COVERED:

 This limited warranty is provided only to the original owner and his or her 

spouse (“Purchaser’) of the residence where the Products are originally installed . This warranty is not 

transferable except according to terms stated on the applicable website identified below under Registration 

Requirements . Company has the right to request any and all proof of Product purchase or installation and/or 

closing date of the residence .

WHAT COMPANY WILL DO:

 Company may request proof of Product purchase and/or installation in 

order to provide Product parts under this limited warranty . As Company’s only responsibility and Purchaser’s 

only remedy under this limited warranty, Company will furnish a replacement part to the licensed 

HVAC service provider, without charge for the part only, to replace any Product part that fails due to a 

manufacturing defect under normal use and maintenance . The Purchaser must pay for any and all shipping 

and handling charges and other costs of warranty service for the replacement part . If a Product part is 

not available, Company will, at its option, provide a free suitable substitute part or provide a credit in the 

amount of the then factory selling price for a new suitable substitute part to be used by the Purchaser 

towards the retail purchase price of a new Company product . Any new Product purchase shall be at 

Purchaser’s sole cost and expense including, but not limited to, all shipping, removal, and installation costs 

and expenses .

REGISTRATION REQUIREMENTS:

 All Products must be properly registered online by the Purchaser 

within sixty (60) days after the Commencement Date to receive the registered limited warranty terms . To 

register online, go to:

http://www .trane .com/Residential/For-Owners/Warranties or  

http://www .americanstandardair .com/servicesupport/pages/warranty .aspx

and click “Begin Online Registration .” If a Purchaser does not register within this stated time period, the 

base limited warranty terms shall apply .

ELIGIBILITY REQUIREMENTS:

 The following items are required in order for the Products to be 

covered under this limited warranty:

• The Products must be in the same location where they were originally installed .

• The Products must be properly installed, operated, and maintained by a licensed HVAC service 

provider in accordance with the Product specifications or installation, operation, and maintenance 

instructions provided by Company with each Product . Failure to conform to such specifications and/or 

instructions shall void this limited warranty . Company may request written documentation showing the 

proper preventative maintenance .

• All Product parts replaced by Company under this limited warranty must be given to the servicing 

provider for return to Company .

• Air handlers, air conditioners, heat pumps, cased or uncased coils and stand-alone furnaces must 

be part of an Air Conditioning, Heating, and Refrigeration Institute rated and matched system or 

a specification in a Company provided bulletin or otherwise approved in writing by a Company 

authorized representative .

GW-658-4217

GW-658-4217

EXCLUSIONS:

 The following are not covered by this limited warranty:

• Labor costs including, but not limited to, costs for diagnostic calls or the removal and reinstallation of 

Products and/or Product parts.

• Shipping and freight expenses required to ship Product replacement parts.

• Failures, defects, or damage (including, but not limited to, any loss of data or property) caused by (1) 

any third party product, service, or system connected or used in conjunction with the Products; (2) 

any use that is not designed or intended for the Products; (3) modification, alteration, abuse, misuse, 

negligence, or accident; (4) improper storage, installation, maintenance, or operation including, but not 

limited to, operation of electrical equipment at voltages other than the range specified on the Product 

nameplate; (5) any use in violation of written instructions or specifications provided by Company; (6) 

any acts of God including, but not limited to, fire, water, storms, lightning, or earthquakes; or any theft 

or riots; or (7) a corrosive atmosphere or contact with corrosive materials such as, but not limited 

to, chlorine, fluorine, salt (provided that indoor and outdoor coils will only be covered if a Sea Coast 

Kit is installed), sulfur, recycled waste water, urine, fertilizers, rust, or other damaging substances or 

chemicals.

• Products purchased direct including, but not limited to, Internet or auction purchases and purchases 

made on an uninstalled basis.

• Cabinets or cabinet pieces that do not affect product performance, air filters, refrigerant, refrigerant 

line sets, belts, wiring, fuses, surge protection devices, non-factory installed driers, and Product 

accessories (unless otherwise specified).

• Increased utility usage costs.

REFRIGERANT POLICY: (1) Manufacturer-Installed Refrigerant: Beginning on January 1, 2010, 

R-22 refrigerant will no longer be used as a manufacturer-installed refrigerant as required by 

federal regulation. All Products with manufacturer-installed refrigerant will include R410-A 

refrigerant. Any and all expenses or costs associated with replacing Product parts that are not 

R-410A compatible will not be covered by the terms and conditions of this limited warranty. (2) 

Non-Manufacturer installed Refrigerant: For Products manufactured and sold by the Company 

without refrigerant, only manufacturer approved and genuine alternate refrigerants shall 

be used. The use of contaminated, counterfeit, non-genuine, or non-manufacturer approved 

alternate refrigerant will void this limited warranty. (3) All Products: Products include a liquid 

line filter drier which must be replaced when a compressor replacement is necessary. A suction 

line filter drier must be added for compressors defined as burnouts and failure to do so will 

void this warranty. Non-approved refrigerant and/or non-approved refrigerant system additives 

including, but not limited to dyes will void this limited warranty.

ADDITIONAL TERMS:

THIS LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER 

WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS 

OR IMPLIED, IN LAW OR IN FACT. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE APPLICABLE 

PRODUCT WARRANTY. COMPANY DOES NOT AUTHORIZE ANY PERSON TO CREATE FOR IT ANY 

OBLIGATION OR LIABILITY IN CONNECTION WITH THE PRODUCTS.

NOTWITHSTANDING ANYTHING IN THIS LIMITED WARRANTY TO THE CONTRARY, 

COMPANY SHALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, 

SPECIAL AND/OR PUNITIVE DAMAGES, WHETHER BASED ON CONTRACT, WARRANTY, 

TORT (INCLUDING, BUT NOT LIMITED TO, STRICT LIABILITY OR NEGLIGENCE), PATENT 

INFRINGEMENT, OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 

COMPANY’S MAXIMUM LIABILITY HEREUNDER IS LIMITED TO THE ORIGINAL PURCHASE PRICE 

OF THE PRODUCTS.

No action arising out of any claimed breach of this limited warranty may be brought by a Purchaser more 

than one (1) year after the cause of action has arisen .

This limited warranty gives you specific legal rights, and you may also have other rights as otherwise 

permitted by law . If this Product is considered a consumer product, please be advised that some local 

laws do not allow limitations on incidental or consequential damages, how long a warranty lasts based on 

registration, or how long an implied warranty lasts, so that the above limitations may not fully apply . Refer 

to your local laws for your specific rights under this limited warranty .

Consumer Relations

20 Corporate Woods Dr . 

Bridgeton, MO 63044

Or visit our website at 

www.trane.com

 or 

www.americanstandardair.com

Summary of Contents for EHUMD800ASM00BA

Page 1: ...200 Troup Highway Tyler TX 75711 9010 READ AND SAVE THESE INSTRUCTIONS Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions EHUMD800ASM00BA EHUMD800BSMLCBA Envirowise Steam Humidifier 32 5092 03 ...

Page 2: ...cess panels until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system ELECTRICAL SHOCK HAZARD If the humidifier starts up responding to a call for humidity during maintenance severe bodily injury or death from electrical shock could occur Follow the procedures in this manual before performing se...

Page 3: ...Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your recent steam humidifier purchase We appreciate your business and are pleased to add your name to our growing list of customers You have invested in the highest quality equipment available Your humidifier w...

Page 4: ... is illuminated green When the canister is being filled or replenished with water the Fill light illuminates green When the canister is being drained the Drain light illuminates green During initial start up with a new canister the humidifier may run through a series of fill drain cycles until the conductivity of the water is in a range that allows normal operation During this time the Steam light...

Page 5: ...rent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects over current which can be caused by failure to drain or other system failures Call your heating and air conditioning dealer for service HUMIDIFIER CONTROL OPERATING INSTRUCTIONS The control provided...

Page 6: ... LED stops flashing disconnect main electrical power to humidifier 3 Remove front panel 4 Pull three wires off posts on top of canister Two large electrode conductors and one water level probe conductor 5 Loosen hose clamp at top of canister 6 Slide hose off top of canister 7 Slide canister up and out of drain assembly Discard canister 8 Remove O ring from drain assembly using small screw driver 9...

Page 7: ... showing the proper preventative maintenance All Product parts replaced by Company under this limited warranty must be given to the servicing provider for return to Company Air handlers air conditioners heat pumps cased or uncased coils and stand alone furnaces must be part of an Air Conditioning Heating and Refrigeration Institute rated and matched system or a specification in a Company provided ...

Page 8: ...nger twenty 20 years TABLE 1 continued FURNACES First digit may be a T or an A UD1 DD1 UD1 H DD1 H UD2 DD2 UE1 DE1 Base Limited Warranty Period Parts five 5 years Heat Exchanger twenty 20 years Registered Limited Warranty Period Parts ten 10 years Heat Exchanger twenty 20 years S9V2 S9X2 UC1 DC1 UD2 V DD2 V UD2 C V DD2 C V UH1 DH1 UX1 DX1 UH2 DH2 UHM DHM Base Limited Warranty Period Parts five 5 y...

Page 9: ...to original owner purchase date and install location will be required including a service diagnosis of failure The purchaser is responsible for all costs of warranty service including but not limited to any related service labor or diagnosis calls The purchaser relinquishes all rights to ownership of the returned unit SPECIFIC TERMS FOR COMMERCIAL APPLICATIONS Base Limited Warranty Period Applies ...

Page 10: ...s five 5 years GW 658 4217 FC GW 658 4217 CONDITIONS SPÉCIFIQUES POUR LES UNITÉS TRIPHASÉES Modèles allant jusqu à 5 tonnes destinés aux bâtiments RÉSIDENTIELS UNITÉS EXTÉRIEURES TRIPHASÉES 2TTA 4TTA 4TWA 4A7C 4A6C UNITÉS MONOBLOCS TRIPHASÉES 4TCY4 4TCX3 4TCC3 4WCZ6 4DCZ6 4WCY4 4DCY4 4WCX3 4WCC3 4YCZ6 4YCY4 4YCX3 4YCC3 Période de validité de base de la garantie limitée Serpentin extérieur pièces d...

Page 11: ...ice de garantie notamment mais non exclusivement tout service de main d œuvre ou appel de diagnostic L acheteur renonce à tout droit de propriété sur l unité renvoyée CONDITIONS SPÉCIFIQUES POUR LES APPLICATIONS COMMERCIALES La durée de garantie limitée de base s applique pour tous les systèmes de régulation produits de zonification humidificateurs déshumidificateurs et ventilateurs à récupération...

Page 12: ...ur douze 12 ans serpentins pièces de remplacement dix 10 ans échangeur de chaleur vingt 20 ans TABLEAU 1 suite CHAUDIÈRES À AIR CHAUD la première lettre peut être un T ou un A UD1 DD1 UD1 H DD1 H UD2 DD2 UE1 DE1 Période de validité de base de la garantie limitée Pièces de remplacement cinq 5 ans échangeur de chaleur vingt 20 ans Période de validité de la garantie limitée pour les produits enregist...

Page 13: ...ertu de la présente garantie limitée doivent être remises au prestataire de service pour être retournées à la Société Les centrales de traitement d air climatiseurs pompes à chaleur serpentins en boîtier ou sans boîtier et chaudières à mazout doivent faire partie d un système reconnu par l ACHRI Institut de climatisation chauffage et refroidissement ou d une spécification apparaissant dans un bull...

Page 14: ... sur la partie supérieure de la cartouche Deux gros conducteurs d électrode et un conducteur de capteur de niveau d eau 5 Desserrez la bride de serrage située sur le dessus de la cartouche 6 Glissez le boyau du dessus de la cartouche 7 Glissez la cartouche vers le haut et hors de l assemblage d évacuation Jetez la cartouche 8 R etirez le joint torique de l assemblage d évacuation au moyen d un pet...

Page 15: ...iveau actuel inférieur à 75 du courant de fonctionnement maximal L humidificateur continue de fonctionner mais à capacité réduite Rouge continu Problème de fonctionnement avec l humidificateur L humidificateur s éteint Se produit lorsque l unité détecte une surintensité qui peut être causée par une défaillance d évacuation ou d autres défaillances du système Appelez votre concessionnaire de chauff...

Page 16: ...he le voyant On Off marche arrêt s allume en vert Lorsque la cartouche est remplie ou ravitaillée en eau le voyant Fill remplissage s allume en vert Lorsque la cartouche se vide le voyant Drain évacuation s allume en vert Durant la mise en marche initiale avec une nouvelle cartouche l humidificateur peut passer à travers une série de cycles de remplissage d évacuation jusqu à ce que la conductivit...

Page 17: ...ouche 90 1522 Sortie de vapeur Évacuation Eau d alimentation Godet d évacuation Robinet de vidange Cartouche Électrodes Capteur de niveau élevé d eau Orifice de contrôle du débit Robinet de remplissage d admission Débordement Remplissage Godet de remplissage Merci d avoir acheté un humidificateur à vapeur Nous vous remercions d avoir fait cet achat et nous sommes heureux d ajouter votre nom à notr...

Page 18: ...branchée Respectez la procédure d arrêt indiquée dans ce manuel avant d effectuer toute procédure de service ou d entretien sur toute pièce du système DANGER DE CHOC ÉLECTRIQUE Si l humidificateur se met en marche en réponse à une demande d humidité pendant une procédure d entretien des blessures graves ou mortelles peuvent survenir à la suite d un choc électrique Respectez les procédures décrites...

Page 19: ...1 9010 LIRE ET CONSERVER CES DIRECTIVES Humidificateur à vapeur résidentiel Guide d utilisation Comprend les directives de sécurité et de fonctionnement EHUMD800ASM00BA EHUMD800BSMLCBA Envirowise humidificateur à vapeur 32 5092 03 10012948 B2207982A 7 18 ...

Reviews: