DISPLAY PANEL

TABLE 1 – Display Panel

Indicator

Light

Function

Off

Humidifier is turned off or not receiving power .

Solid 

Green

Humidifier is turned on .

Flashing 

Green

Humidifier is preparing to turn on . Occurs if power is 
disconnected, then restored with switch ON . Flashes for 
one minute .

Solid 

Green

Normal Operation . Fill valve is energized allowing water 
to flow into canister via fill cup . (Does not illuminate when 
tempering water during drain cycle .)

Flashing 

Green

Fill and Drain Valves are pulsing to dislodge mineral build-up 
in canister . Flashes 10 times in four seconds .

Solid Red

Fault Mode . Indicates canister needs water but cannot fill . 
Humidifier shuts down . (Occurs if high water probe does not 
detect water after fill valve is energized for 40 minutes .) 

Solid 

Green

Normal Operation . Humidistat is calling for steam and 
humidifier is operating .

Solid 

Yellow

Humidifier is operating but is not delivering steam at rated 
capacity . Occurs if humidifier has operated for 168 hours 
at less than rated capacity due to low water conductivity . 
Light will turn green once water conductivity increases and 
humidifier is delivering rated capacity .

Flashing 

Green

Humidifier is preparing to drain . (Fill valve is open 
tempering water in canister .) Occurs when humidifier 
is turned off, at end of season drain (72 hours with no 
operation) and during forced drain down (168 hours of 
operation with no drain activity .) 

Fill and Drain Valves are pulsing to dislodge mineral build-up 
in canister . Flashes 10 times in four seconds .

Solid 

Green

Drain valve is energized and open, draining canister . Valve 
remains energized for four minutes .

Indicates end of season shut-down . Occurs if humidifier 
does not receive call for humidity in 72 hours . Light remains 
on for 24 hours . 

Flashing 

Red

Canister has reached the end of its life and needs to be 
replaced . Occurs after humidifier has operated for at least 
168 hours and for an additional 24 hours at a current level 
below 75% of the maximum operating current . Humidifier 
continues to operate, but at reduced capacity .

Solid Red

Operational problem with humidifier . Humidifier shuts 
down . Occurs when unit detects over-current which can be 
caused by failure to drain or other system failures . Call your 
heating and air conditioning dealer for service .

HUMIDIFIER CONTROL & OPERATING INSTRUCTIONS

The control provided with your humidifier is mounted either in your return 
air duct or on a wall in the living space . The control has a set of contacts 
which close when the RH is below the set point . That signal tells the 
humidifier to energize the electrodes in the canister to generate steam, 
provided the indoor unit blower is on . If the blower activation relay is 
installed, a call for humidity will turn on the indoor unit blower .
It is important to anticipate changes in outdoor temperature and adjust 
the setting accordingly to avoid excessive condensation when outdoor 
temperature is low . For example, with an outdoor temperature of 20°F the 
correct setting will be 35% . If the temperature is expected to fall to 0°F 
that evening, then merely reduce the setting to 25% several hours prior to 
the temperature change .
See 

Table 2

 for the recommended settings . These settings, which are 

based on years of research, represent a compromise between humidity 
levels that would be most desirable for comfort and humidity levels that 
are suitable for protection of your home and to avoid condensation on 
your windows . For example, a wintertime indoor humidity of 50% may be 
considered ideal for comfort, but unfortunately, it probably would result 
in condensation, which can cause damage to your home . Observing the 
recommended humidity levels on your Humidifier Control is an important 
safeguard . Condensation of water on the inside surface of windows in 
the form of fogging or frost is usually an indication of too much humidity . 
This same condensation can occur in other areas in your home, possibly 
resulting in damage .

TABLE 2 – Outdoor Temperature/Indoor Relative Humidity

 

Outside Temperature  

Recommended RH

 +40°F 

45%

 +30°F 

40%

 +20°F 

35%

 +10°F 

30%

 0°F 

25%

 –10°F 

20%

 –20°F 

15%

Summary of Contents for EHUMD800ASM00BA

Page 1: ...200 Troup Highway Tyler TX 75711 9010 READ AND SAVE THESE INSTRUCTIONS Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions EHUMD800ASM00BA EHUMD800BSMLCBA Envirowise Steam Humidifier 32 5092 03 ...

Page 2: ...cess panels until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system ELECTRICAL SHOCK HAZARD If the humidifier starts up responding to a call for humidity during maintenance severe bodily injury or death from electrical shock could occur Follow the procedures in this manual before performing se...

Page 3: ...Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your recent steam humidifier purchase We appreciate your business and are pleased to add your name to our growing list of customers You have invested in the highest quality equipment available Your humidifier w...

Page 4: ... is illuminated green When the canister is being filled or replenished with water the Fill light illuminates green When the canister is being drained the Drain light illuminates green During initial start up with a new canister the humidifier may run through a series of fill drain cycles until the conductivity of the water is in a range that allows normal operation During this time the Steam light...

Page 5: ...rent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects over current which can be caused by failure to drain or other system failures Call your heating and air conditioning dealer for service HUMIDIFIER CONTROL OPERATING INSTRUCTIONS The control provided...

Page 6: ... LED stops flashing disconnect main electrical power to humidifier 3 Remove front panel 4 Pull three wires off posts on top of canister Two large electrode conductors and one water level probe conductor 5 Loosen hose clamp at top of canister 6 Slide hose off top of canister 7 Slide canister up and out of drain assembly Discard canister 8 Remove O ring from drain assembly using small screw driver 9...

Page 7: ... showing the proper preventative maintenance All Product parts replaced by Company under this limited warranty must be given to the servicing provider for return to Company Air handlers air conditioners heat pumps cased or uncased coils and stand alone furnaces must be part of an Air Conditioning Heating and Refrigeration Institute rated and matched system or a specification in a Company provided ...

Page 8: ...nger twenty 20 years TABLE 1 continued FURNACES First digit may be a T or an A UD1 DD1 UD1 H DD1 H UD2 DD2 UE1 DE1 Base Limited Warranty Period Parts five 5 years Heat Exchanger twenty 20 years Registered Limited Warranty Period Parts ten 10 years Heat Exchanger twenty 20 years S9V2 S9X2 UC1 DC1 UD2 V DD2 V UD2 C V DD2 C V UH1 DH1 UX1 DX1 UH2 DH2 UHM DHM Base Limited Warranty Period Parts five 5 y...

Page 9: ...to original owner purchase date and install location will be required including a service diagnosis of failure The purchaser is responsible for all costs of warranty service including but not limited to any related service labor or diagnosis calls The purchaser relinquishes all rights to ownership of the returned unit SPECIFIC TERMS FOR COMMERCIAL APPLICATIONS Base Limited Warranty Period Applies ...

Page 10: ...s five 5 years GW 658 4217 FC GW 658 4217 CONDITIONS SPÉCIFIQUES POUR LES UNITÉS TRIPHASÉES Modèles allant jusqu à 5 tonnes destinés aux bâtiments RÉSIDENTIELS UNITÉS EXTÉRIEURES TRIPHASÉES 2TTA 4TTA 4TWA 4A7C 4A6C UNITÉS MONOBLOCS TRIPHASÉES 4TCY4 4TCX3 4TCC3 4WCZ6 4DCZ6 4WCY4 4DCY4 4WCX3 4WCC3 4YCZ6 4YCY4 4YCX3 4YCC3 Période de validité de base de la garantie limitée Serpentin extérieur pièces d...

Page 11: ...ice de garantie notamment mais non exclusivement tout service de main d œuvre ou appel de diagnostic L acheteur renonce à tout droit de propriété sur l unité renvoyée CONDITIONS SPÉCIFIQUES POUR LES APPLICATIONS COMMERCIALES La durée de garantie limitée de base s applique pour tous les systèmes de régulation produits de zonification humidificateurs déshumidificateurs et ventilateurs à récupération...

Page 12: ...ur douze 12 ans serpentins pièces de remplacement dix 10 ans échangeur de chaleur vingt 20 ans TABLEAU 1 suite CHAUDIÈRES À AIR CHAUD la première lettre peut être un T ou un A UD1 DD1 UD1 H DD1 H UD2 DD2 UE1 DE1 Période de validité de base de la garantie limitée Pièces de remplacement cinq 5 ans échangeur de chaleur vingt 20 ans Période de validité de la garantie limitée pour les produits enregist...

Page 13: ...ertu de la présente garantie limitée doivent être remises au prestataire de service pour être retournées à la Société Les centrales de traitement d air climatiseurs pompes à chaleur serpentins en boîtier ou sans boîtier et chaudières à mazout doivent faire partie d un système reconnu par l ACHRI Institut de climatisation chauffage et refroidissement ou d une spécification apparaissant dans un bull...

Page 14: ... sur la partie supérieure de la cartouche Deux gros conducteurs d électrode et un conducteur de capteur de niveau d eau 5 Desserrez la bride de serrage située sur le dessus de la cartouche 6 Glissez le boyau du dessus de la cartouche 7 Glissez la cartouche vers le haut et hors de l assemblage d évacuation Jetez la cartouche 8 R etirez le joint torique de l assemblage d évacuation au moyen d un pet...

Page 15: ...iveau actuel inférieur à 75 du courant de fonctionnement maximal L humidificateur continue de fonctionner mais à capacité réduite Rouge continu Problème de fonctionnement avec l humidificateur L humidificateur s éteint Se produit lorsque l unité détecte une surintensité qui peut être causée par une défaillance d évacuation ou d autres défaillances du système Appelez votre concessionnaire de chauff...

Page 16: ...he le voyant On Off marche arrêt s allume en vert Lorsque la cartouche est remplie ou ravitaillée en eau le voyant Fill remplissage s allume en vert Lorsque la cartouche se vide le voyant Drain évacuation s allume en vert Durant la mise en marche initiale avec une nouvelle cartouche l humidificateur peut passer à travers une série de cycles de remplissage d évacuation jusqu à ce que la conductivit...

Page 17: ...ouche 90 1522 Sortie de vapeur Évacuation Eau d alimentation Godet d évacuation Robinet de vidange Cartouche Électrodes Capteur de niveau élevé d eau Orifice de contrôle du débit Robinet de remplissage d admission Débordement Remplissage Godet de remplissage Merci d avoir acheté un humidificateur à vapeur Nous vous remercions d avoir fait cet achat et nous sommes heureux d ajouter votre nom à notr...

Page 18: ...branchée Respectez la procédure d arrêt indiquée dans ce manuel avant d effectuer toute procédure de service ou d entretien sur toute pièce du système DANGER DE CHOC ÉLECTRIQUE Si l humidificateur se met en marche en réponse à une demande d humidité pendant une procédure d entretien des blessures graves ou mortelles peuvent survenir à la suite d un choc électrique Respectez les procédures décrites...

Page 19: ...1 9010 LIRE ET CONSERVER CES DIRECTIVES Humidificateur à vapeur résidentiel Guide d utilisation Comprend les directives de sécurité et de fonctionnement EHUMD800ASM00BA EHUMD800BSMLCBA Envirowise humidificateur à vapeur 32 5092 03 10012948 B2207982A 7 18 ...

Reviews: